Eur J Obstet Gynecol Reprod Biol. 2021 Mar 2;259:178-184. doi: 10.1016/j.ejogrb.2021.02.029. Online ahead of print.
ABSTRACT
OBJECTIVE: Electrohysterography is a non-invasive technique to monitor uterine activity and has a significantly higher sensitivity compared to conventional external tocodynamometry. Whether this technique could lead to improved obstetrical outcomes is still unknown. In this propensity score matched study, clinical results of the first pilot implementing electrohysterography during labor were evaluated. The hypothesis tested is that electrohysterography will help to optimize uterine activity and thereby lead to fewer obstetric interventions. Secondary outcomes were Apgar score, arterial umbilical pH values, first stage labor duration, episiotomy rate and postpartum vaginal blood loss.
STUDY DESIGN: From November 2017 until October 2018, electrohysterography was introduced as a standard alternative for monitoring uterine activity in high-risk deliveries. It could be applied in case of induced labor, previous cesarean delivery, body mass index ≥30 kg/m2 or an inadequate external tocodynamometry monitoring. Outcomes were compared to a matched group of women in which external tocodynamometry was applied for uterine activity monitoring during labor. These women were identified using propensity scores.
RESULTS: A total of 348 women received electrohysterography as standard method of uterine monitoring during labor. A match (1:1 ratio) was found for 317 women, resulting in a total population of 634 women. No significant differences were seen in obstetric interventions (i.e. cesarean deliveries and assisted vaginal deliveries) between the electrohysterography and tocodynamometry group (P = 0.80). No statistically significant differences were seen regarding the secondary outcomes.
CONCLUSIONS: This first pilot study implementing electrohysterography as monitoring method during labor in a high-risk population did not result in statistically significant differences regarding obstetric interventions, low Apgar scores or low umbilical artery pH values. Therefore, we suggest that electrohysterography causes no harm and we recommend further implementation and evaluation in clinical practice.
PMID:33684672 | DOI:10.1016/j.ejogrb.2021.02.029