Comp Med. 2021 Mar 11. doi: 10.30802/AALAS-CM-20-000089. Online ahead of print.
ABSTRACT
CT (computerized tomography) is a necessary imaging modality for cancer staging and disease monitoring. Rodent models of cancer are commonly studied prior to human clinical trials, but CT in rodents can be difficult due to their small size and constant movement, which necessitates general anesthesia. Because microCT equipment is not always available, clinical CT may be a viable alternative. Limitations of microCT and clinical CT include biosecurity, anesthesia to limit image distortion due to motion, and cost. To address several of these constraints, we created a 3D-printed apparatus that accommodated simultaneous imaging of as many as 9 rats under gas anesthesia. Rats were anesthetized in series and placed in a 3 × 3 arrangement. To assess differences in attenuation between individual chambers and rows or columns in the device, we first imaged a standardized phantom plug as a control. We hypothesized that attenuation of specific rat organs would not be affected regardless of the location or position in the 3D-printed device. Four organs-liver, kidney, femur, and brain-were evaluated in 9 rats. For both the phantom and kidneys, statistically significant, but clinically negligible, effects on attenuation were noted between rows but not between columns. We attribute this finding to the absence of a top layer of the apparatus, which thus created asymmetric attenuation and beam hardening through the device. This apparatus allowed us to successfully image 9 rats simultaneously in a clinical CT machine, with negligible effects on attenuation. Planned improvements in this apparatus include completely enclosed versions for biosecure imaging.
PMID:33706858 | DOI:10.30802/AALAS-CM-20-000089