Clin Oncol (R Coll Radiol). 2021 Sep 7:S0936-6555(21)00326-5. doi: 10.1016/j.clon.2021.08.012. Online ahead of print.
ABSTRACT
AIMS: With interest in normal tissue sparing and dose-escalated radiotherapy in the treatment of inoperable locally advanced non-small cell lung cancer, this study investigated the impact of motion-managed moderate deep inspiration breath hold (mDIBH) on normal tissue sparing and dose-escalation potential and compared this to planning with a four-dimensional motion-encompassing internal target volume or motion-compensating mid-ventilation approach.
MATERIALS AND METHODS: Twenty-one patients underwent four-dimensional and mDIBH planning computed tomography scans. Internal and mid-ventilation target volumes were generated on the four-dimensional scan, with mDIBH target volumes generated on the mDIBH scan. Isotoxic target dose-escalation guidelines were used to generate six plans per patient: three with a target dose cap and three without. Target dose-escalation potential, normal tissue complication probability and differences in pre-specified dose-volume metrics were evaluated for the three motion-management techniques.
RESULTS: The mean total lung volume was significantly greater with mDIBH compared with four-dimensional scans. Lung dose (mean and V21 Gy) and mean heart dose were significantly reduced with mDIBH in comparison with four-dimensional-based approaches, and this translated to a significant reduction in heart and lung normal tissue complication probability with mDIBH. In 20/21 patients, the trial target prescription dose cap of 79.2 Gy was achievable with all motion-management techniques.
CONCLUSION: mDIBH aids lung and heart dose sparing in isotoxic dose-escalated radiotherapy compared with four-dimensional planning techniques. Given concerns about lung and cardiac toxicity, particularly in an era of consolidation immunotherapy, reduced normal tissue doses may be advantageous for treatment tolerance and outcome.
PMID:34503896 | DOI:10.1016/j.clon.2021.08.012