Eur J Radiol. 2022 Mar 17;150:110261. doi: 10.1016/j.ejrad.2022.110261. Online ahead of print.
ABSTRACT
PURPOSE: To primarily evaluate the diagnostic performance of the monoexponential and intravoxel incoherent motion (IVIM) diffusion weighted imaging (DWI) models for differentiating between nonhypervascular pancreatic neuroendocrine tumors (PNETs) and pancreatic ductal adenocarcinomas (PDACs).
METHODS: 63 patients with PNETs (35 nonhypervascular PNETs and 28 hypervascular PNETs) and 164 patients with PDACs were retrospectively enrolled in the study and underwent multiple b-value DWI. Intraobserver and interobserver reliabilities of DWI parameters were assessed by using the intraclass correlation coefficient (ICC). The parameters of apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) of nonhypervascular PNETs were compared with PDACs and hypervascular PNETs using the independent sample t test or the Mann-Whitney U test. The diagnostic performance was evaluated using receiver operating characteristic (ROC) analysis.
RESULTS: All DWI parameters values showed good to excellent intra- and interobserver agreements (ICC = 0.743-0.873). Nonhypervascular PNETs had significantly lower ADC and D, but significantly higher f than PDACs (P = 0.005, P < 0.001 and P < 0.001, respectively). ADC, D and f of nonhypervascular PNETs were lower than hypervascular PNETs (P = 0.001, <0.001 and 0.093, respectively). D* of nonhypervascular PNETs showed no statistically significant differences with PDACs and hypervascular PNETs (P = 0.809 and 0.420). D showed a higher area under the curve (AUC), followed by ADC and f (AUC = 0.885, 0.665 and 0.740, respectively) in differentiating nonhypervascular PNETs from PDACs.
CONCLUSION: Monoexponential and IVIM diffusion models are valuable to differentiate nonhypervascular PNETs from PDACs. D showed better performance than f and ADC.
PMID:35316674 | DOI:10.1016/j.ejrad.2022.110261