A new instrument to assess physical function in stroke patients: the Dubousset function test and its validity, reliability, responsiveness

Neurol Res. 2023 Sep 21:1-9. doi: 10.1080/01616412.2023.2257439. Online ahead of print.

ABSTRACT

AIM: The Dubousset Functional Test (DFT) ia a practical four-component assessment test to assess the physical function and balance capacities. The study aimed to examine the reliability, validity, responsiveness of the DFT in stroke survivors.

METHODS: This study included a total of 57 post-stroke patients (age 60.16 ± 15.08 years). The participants were divided into two groups according to the duration of stroke (6-12 months, 12 months and more). Reliability of DFT test was evaluated with Intraclass Correlation Coefficient (ICC). The correlation between the DFT and The Timed Up and Go test (TUG), dual-task TUG, Functional Reach Test (FRT), 3-meter backward walk test (3MBWT), Tinetti Performance Oriented Mobility Assessment (POMA) was used for the validity.

RESULTS: For total post-stroke patients, ICC values were between 0.899 and 0.984 (excellent agreement). For stroke patients have 6-12 months stroke duration ICC values were between 0.831 and 0.988 (excellent agreement). For post-stroke patients have 6-12 months stroke duration ICC values were between 0.858 and 0.992 (excellent agreement). For total stroke post-patients the correlation with four component of DFT and TUG, dual-task TUG, FRT, 3MBWT and POMA was found to be statistically significant (p < 0.001).

CONCLUSION: The DFT has excellent reliability and validity in post-stroke patients. Therefore, it may be a clinically suitable test for detecting balance and physical function.

PMID:37733422 | DOI:10.1080/01616412.2023.2257439