Comparison of two multiplex PCR tests for common pathogen detection in hospitalized children with acute respiratory infection

J Infect Dev Ctries. 2023 Oct 31;17(10):1474-1479. doi: 10.3855/jidc.17999.

ABSTRACT

INTRODUCTION: Multiplex PCR methods have significantly improved the diagnosis of acute respiratory tract infections (ARTIs) in children. The ResP-CE System coupled with capillary electrophoresis is a highly specialized, automated, and expensive technology for detecting common pathogens in ARTIs. The XYRes-MCA System, a remarkably less expensive multiplex PCR instrument, employs hybridization for the detection of ARTI pathogens. Both methods detect 9 common microorganisms in ARTIs, i.e., RSV, FLUAV, FLUBV, ADV, PIV, HMPV, HBOV, HCOV, and MP. In this study, we aimed to compare the performance of these two methods in the detection of pathogens from sputum specimens collected from children with ARTIs.

METHODOLOGY: Sputum specimens were collected from 237 hospitalized children with ARTIs. Nucleic acid was extracted on an automated workstation. The ResP-CE and XYres-MCA systems were applied to detect pathogens from the samples, and the test result agreement between the two methods was evaluated using Kappa statistics.

RESULTS: The ResP-CE and XYres-MCA identified pathogens, single or in combination, in 151 (63.7%) and 171 (72.1%) of 237 samples, respectively. Approximately 85% of positive samples identified by either method contained a single pathogen. Moderate to almost perfect concordance between the two methods was found in detecting the following 7 pathogens: RSV, FLUAV, FLUBV, PIV, HMPV, HBOV, and MP.

CONCLUSIONS: These two methods are comparable in detecting common pathogens of ARTIs in children. As XYres-MCA analysis is more cost-effective, it could play an important role in diagnosing ARTIs in children in less economically developed regions.

PMID:37956382 | DOI:10.3855/jidc.17999