Drugs. 2025 Feb 13. doi: 10.1007/s40265-025-02157-1. Online ahead of print.
ABSTRACT
BACKGROUND AND OBJECTIVE: Bimatoprost implant 10 µg (Durysta) is an intracameral biodegradable implant that releases bimatoprost to lower intraocular pressure (IOP). The purpose of this study was to prospectively collect effectiveness and safety data after administration of the implant in patients with open-angle glaucoma or ocular hypertension.
METHODS: This phase IV, multicenter, prospective, observational, open-label, 18-month study (ARGOS) enrolled adult patients with open-angle glaucoma or ocular hypertension who were scheduled to receive the bimatoprost implant in one or both eyes. Data collected included IOP, use of topical IOP-lowering medications, treatment-emergent adverse events, and central corneal endothelial cell density. The primary endpoint was the proportion of primary (first-treated) eyes that received no additional (new) IOP-lowering treatment per standard medical care through month 6 after the implant administration.
RESULTS: A total of 217 patients (341 eyes) were enrolled, and 132 patients (60.8%) and 203 eyes (59.5%) completed the study. Most patients were on topical IOP-lowering medication before receiving the implant. After implant administration, the proportion of primary eyes that had received no additional treatment was 88.6% (95% confidence interval 86.6-90.6) at month 6 (primary endpoint) and remained high throughout the follow-up: 83.7% (95% confidence interval 80.2-87.3) at month 12 and 77.7% (95% confidence interval 73.4-82.1) at month 18. Intraocular pressure was reduced after implant administration, with mean changes in IOP from baseline at follow-up visits ranging from – 1.0 to – 2.0 mm Hg. The mean number of topical IOP-lowering medications used was also reduced, from 1.8 at baseline to 0.9 at month 12 and 1.0 at month 18. Increased IOP and dry eye were the most common ocular treatment-emergent adverse events. The mean percentage change in central corneal endothelial cell density from baseline at month 18 (central reading center evaluation) was – 3.47%. In qualitative interviews, most patients (84%, 21/25) reported overall satisfaction with their treatment outcomes.
CONCLUSIONS: The bimatoprost implant helped control IOP and decrease topical medication use. Throughout the 18 months after implant administration, an estimated 77.7% of eyes required no new added medication for IOP management. Patient-reported outcomes were favorable, and the safety profile of the implant was acceptable.
CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT04647214, registered 23 November, 2020.
PMID:39946034 | DOI:10.1007/s40265-025-02157-1