Ophthalmol Ther. 2025 Sep 29. doi: 10.1007/s40123-025-01245-5. Online ahead of print.
ABSTRACT
INTRODUCTION: To compare the U.S. Food and Drug Administration (FDA) premarket approval (PMA) trials of topography-guided laser in situ keratomileusis (TG-LASIK) and ray tracing-guided LASIK (RT-LASIK) for the treatment of myopia and myopic astigmatism.
METHODS: This comparative study was conducted between TG-LASIK (P020050/S012; Alcon Laboratories, Inc., Fort Worth, TX, USA) with Allegretto Wave Eye-Q laser and topography-guided custom ablation treatment planning software, and “WaveLight Plus” RT-LASIK (P020050/S043; Alcon Laboratories, Inc.) using the WaveLight EX500 excimer laser and InnovEyes Sightmap. Clinical outcomes were compared, including visual and refractive measures, astigmatic correction, mesopic contrast sensitivity, higher-order aberrations, and patient-reported outcomes.
RESULTS: This analysis included 249 eyes (212 patients) that underwent TG-LASIK and 336 eyes (168 patients) that underwent RT-LASIK. At 12 months, uncorrected distance visual acuity of 20/16 or better (64.8% TG-LASIK vs. 70.2% RT-LASIK) and 20/20 or better (92.6% TG-LASIK vs. 94.4% RT-LASIK) did not differ statistically between platforms. However, more TG-LASIK eyes had 20/10 or better (15.7% vs. 2.5%, P < 0.001) and 20/12.5 or better (34.4% vs. 26.4%, P = 0.044) than RT-LASIK eyes. Both platforms demonstrated comparable refractive predictability and stability (P > 0.05). For preoperative cylinder between – 1.00 to – 4.00 D, RT-LASIK showed greater astigmatic overcorrection (P < 0.05). At 3 months, RT-LASIK showed higher mesopic contrast sensitivity at 3, 6, and 12 cycles per degree under glare, with more eyes achieving clinically significant gains compared to TG-LASIK (P < 0.001). Both platforms induced changes in total higher-order aberrations, although not clinically significant. RT-LASIK also reduced spherical aberration from baseline. Both procedures showed a reduction in symptom severity for glare, halos, starburst, double vision, and dry eye.
CONCLUSIONS: While TG-LASIK showed superior visual acuity outcomes, RT-LASIK was associated with higher contrast sensitivity; however, both platforms demonstrate excellent visual and refractive outcomes. The majority of published studies are consistent with FDA PMA trends, showing potential reductions in spherical aberration and higher rates of 20/20 or better visual acuity with RT-LASIK.
PMID:41016970 | DOI:10.1007/s40123-025-01245-5