Original Designed Uniportal-Bichannel Spinal Endoscopic System (UBiSES) for Foraminoplasty in Percutaneous Endoscopic Transforaminal Discectomy

Orthop Surg. 2021 Sep 15. doi: 10.1111/os.13050. Online ahead of print.

ABSTRACT

OBJECTIVE: The study introduced uniportal-bichannel spinal endoscopic system (UBiSES) and explored the feasibility of applying UBiSES to conduct lumbar foraminoplasty in percutaneous endoscopic transforaminal discectomy (PETD).

METHODS: This is a cohort study. 36 patients confirmed as L5/S1 lumbar disc herniation (LDH) in our hospital from March, 2019 to November, 2019 were enrolled. 36 patients were divided into two groups named the UBiSES group (n = 18, male: female = 8:10) and the TESSYS group (n = 18, male: female = 10:8). The average age of the UBiSES group and the TESSYS group were 40.94 ± 12.39 years old and 39.78 ± 13.02 years old respectively. PETD via uniportal-bichannel foraminoplasty assisted by UBiSES was adopted on the UBiSES group while PETD via conventional foraminoplasty was performed on the TESSYS group. One experienced surgeon with more than 4000 cases of lumbar surgery performed PETD on all patients. The demographic data, the duration of working cannula placement (minutes), decompression time (minutes), radiation exposure time (seconds), complications, Visual Analogue Scale (VAS), Oswestry Disability Index (ODI) scores and modified MacNab criteria were recorded and analyzed. The magnetic resonance imaging (MRI) and computed tomography (CT) were conducted to evaluate the radiographic improvement.

RESULTS: PETD via lumbar foraminoplasty was successfully performed in all cases. The follow-up points were 3 months, 6 months, and 12 months. The average follow-up period of all patients was 15.78 ± 2.29 months. There was no statistic difference in age (P = 0.81), sex (P = 0.51) and follow-up (P = 0.14) between two groups. The duration of working cannula placement was 19.08 ± 2.30 min in the UBiSES group and 24.90 ± 4.71 min in the TESSYS group and there was significant difference between two groups (P < 0.05). There was no statistic difference in decompression time between the UBiSES group (44.18 ± 5.70 min) and the TESSYS group (47.46 ± 5.96 min) (P = 1.70). The radiation exposure time was 28.00 ± 4.70 s in the UBiSES group and 40.50 ± 5.73 s in the TESSYS group respectively, and has significant difference between two groups (P < 0.05). Furthermore, there was significant different in the duration of working cannula placement and radiation exposure time in male or female between the UBiSES group and the TESSYS group (P < 0.05). For male or female, no difference observed in decompression time and follow-up period between two groups. Postoperative VAS of low back and leg at every follow-up point (1 day, 3 months, 6 months, 12 months) was improved significantly in both groups compared with their preoperative VAS (P < 0.05). The postoperative ODI (3 months, 6 months, 12 months) has decreased significantly in both the UBiSES group and the TESSYS group compared with their preoperative ODI (P < 0.05). 94.44% patients received an excellent or good recovery in the UBiSES group and 88.89% for the TESSYS group. There was no poor result reported in both groups. The radiographic images showed satisfactory foraminoplasty and sufficient decompression of nerve in both groups. No postoperative complications were observed during follow-ups in the UBiSES group. Two patients in the TESSYS group experienced postoperative dysesthesia and the symptom was disappeared in 5 days and 7 days respectively with dexamethasone and neurotrophic drugs treatment.

CONCLUSIONS: The original designed UBiSES could effectively and safely enlarge the foramen with an extensive surgical view and space under full-time and real-time visualization and get satisfactory efficacy.

PMID:34523790 | DOI:10.1111/os.13050