OBJECTIVES: This study evaluated the linear dimensional change of polymerization of three materials and two techniques of the union of molding transfers for implant-supported prostheses used in the open-tray technique.

MATERIALS AND METHODS: A nylon maxilla-shaped matrix was made, two osseous integrated implants were installed, and, over these two, straight conical mini-pillars were installed. Open-tray impression transfers were attached to the mini-pillars, and a silicone guide was made to standardize the connections between the transfers. The samples were divided into six groups (n = 20): PA (Pattern Resin LS, chemically activated acrylic resin in the single step technique); DU (Durallay, chemically activated acrylic resin in the single step technique); BI (Protemp4, bisacrylic resin in the single step technique); PAC (Pattern Resin LS in sectioning and joining of segments technique); DUC (Durallay, in sectioning and joining of segments technique); and BIC (Protemp4, in sectioning and joining of segments technique). The linear dimensional change values that occurred among these transfers were measured in a profile projector (VB300; Starret) coupled to the Quadra Check device, with a resolution of 0.001 mm, performed by a single calibrated operator.

STATISTICAL ANALYSIS: Data were submitted to a two-way analysis of variance and Tukey’s test (p < 0.01).

RESULTS: Statistically significant mean values were found in all comparisons. The PA showed the lowest mean values (µm) of linear dimensional change, both in the single-step technique and in the sectioning and joining technique, in the following order: BI 255.73 (3.81), DU 173.75 (2.30), PA 95.97 (3.20), BIC 23.82 (1.71), DUC 20.85 (2.53), and PAC 13.27 (2.09). The single-step technique showed the worst results, regardless of the material.

CONCLUSION: The sectioning and joining technique reduced the dimensional change in all materials, and the Pattern Resin LS showed the lowest shrinkage mean values, followed by Durallay and Protemp4.