Categories
Nevin Manimala Statistics

Measurement of the Brain Volume/Liver Volume Ratio by Three-Dimensional MRI in Appropriate-for-Gestational Age Fetuses and Those With Fetal Growth Restriction

J Magn Reson Imaging. 2021 Jun 21. doi: 10.1002/jmri.27792. Online ahead of print.

ABSTRACT

BACKGROUND: Fetal growth restriction (FGR) is associated with a high fetal brain volume/liver volume (FBV/FLV) ratio. Ultrasound may not always be reliable, which has prompted further investigation of MRI techniques.

PURPOSE: To determine the relationship between FBV/FLV ratio, as measured by MRI, and gestational age (GA) in normal fetuses and those with FGR.

STUDY TYPE: Retrospective.

POPULATION: One hundred and forty seven singleton pregnancies including 105 appropriate-for-gestational age (AGA) fetuses and 42 FGR fetuses.

FIELD STRENGTH/SEQUENCE: Three-dimensional fast imaging employing steady-state acquisition at 1.5 T.

ASSESSMENT: The FBV and FLV were measured by three radiologists. The inter- and intraobserver agreements, the correlation between FBV/FLV ratio, and advancing GA were evaluated; the diagnostic value of FBV/FLV ratio was evaluated and compared with head circumference/abdominal circumference (HC/AC) ratio measured by ultrasound.

STATISTICAL TESTS: Intraclass correlation coefficient (ICC) was used to determine inter- and intraobserver agreements. Regression analysis was used to assess the correlation between FBV/FLV ratio and advancing GA. The diagnostic value of the FBV/FLV ratio was examined by the area under the receiver operating characteristic (ROC) curve.

RESULTS: The inter- and intraobserver agreements were excellent with an interobserver ICC of 0.984 and intra-observer ICCs of 0.989, 0.994, and 0.995. The FBV/FLV ratio in AGA fetuses decreased significantly with advancing GA (Pearson correlation coefficient = -0.844). The FBV/FLV ratio in FGR fetuses was significantly higher than that in AGA fetuses. To identify fetuses at high risk for FGR using the FBV/FLV ratio, the area under the ROC curve was 0.978, with an optimal cut-off value of 4.10. The sensitivity of FBV/FLV ratio in identifying FGR was significantly higher than that of HC/AC ratio (0.929 vs. 0.529).

DATA CONCLUSION: An inverse correlation exists between FBV/FLV ratio and advancing GA in normal fetuses. A high FBV/FLV ratio may be used to ascertain fetuses at high risk for FGR.

LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 3.

PMID:34156128 | DOI:10.1002/jmri.27792