J Healthc Qual. 2025 Apr 25. doi: 10.1097/JHQ.0000000000000477. Online ahead of print.
ABSTRACT
INTRODUCTION: Catheter-associated urinary tract infections (CAUTIs) are common complications in patients with traumatic brain injury (TBI) who require indwelling bladder catheters (IBCs). This study examined the impact of an Acute Urinary Retention Algorithm (AURA) nursing protocol that incorporates intermittent catheterization (IC) on CAUTI incidence.
METHODS: A retrospective analysis was conducted on TBI patients with IBCs placed between 2018 and 2022 at a Level I trauma center in Southern California. Catheter-associated urinary tract infection incidence and catheter-associated complications were compared between patients treated with and without the AURA protocol.
RESULTS: Among 73,005 patients with IBC, 255 had TBI and were admitted to the intensive care unit. Only 27 (10.6%) patients had catheters removed through the AURA protocol and had longer dwell times than the nonprotocol patients (2.59 vs. 2.44 days, p < .001). Catheter-associated urinary tract infection incidence was statistically similar between the protocol (7.4%) and nonprotocol groups (3.5%) (p = .327). However, patients who developed CAUTI were more likely to have undergone more than one IC.
CONCLUSIONS: Timely removal of IBCs is crucial to minimizing the risk of CAUTI. This study highlights the underutilization of nurse-driven protocols such as AURA and suggests a careful application of IC in such protocols because of its potential association with increased CAUTI risk.
PMID:40279521 | DOI:10.1097/JHQ.0000000000000477