Categories
Nevin Manimala Statistics

Evaluating the Long-term Effects of Microfocused Ultrasound on Facial Tightening Using Quantitative Instruments: Efficacy and Safety

Aesthetic Plast Surg. 2025 Sep 10. doi: 10.1007/s00266-025-05205-z. Online ahead of print.

ABSTRACT

BACKGROUND: Microfocused ultrasound (MFU) is a non-invasive technique used for facial rejuvenation, yet there is limited quantitative data on its long-term effects. This study aimed to evaluate the long-term efficacy and safety of MFU for facial rejuvenation. We utilized standardized photography along with advanced skin assessment technologies to analyze the impact of MFU on facial morphology, skin function, and patient satisfaction over a 12-month period.

METHODS: A prospective clinical study was conducted on 28 healthy female subjects (age range: 33-55 years) who underwent a single MFU treatment. Comprehensive assessments were performed at baseline and at seven follow-up time points (30 minutes, 1 week, 1 month, 3 months, 6 months, 9 months, and 12 months). Objective measurements included facial volumetric changes nasolabial fold morphology, skin physical parameters, and clinical aesthetic scores. Patient satisfaction and safety data were also collected.

STATISTICAL ANALYSIS: Longitudinal data were analyzed using linear mixed-effects models with subject-specific random intercepts to account for repeated measurements.

RESULTS: Facial volume showed significant immediate increase (5.65 ± 2.15 ml, 95% CI: 4.821-6.486, CV=37.98%, P < 0.001, Cohen’s d = 2.633) post-treatment, followed by progressive tightening, with maximum volume reduction at 3 months (- 3.37 ± 4.79 ml, 95% CI: – 5.227 to – 1.511, CV=142.26%, P < 0.001, Cohen’s d = – 0.703). Both facial and submental regions maintained statistically significant volume reduction through 12 months: Facial region: – 1.86 ± 4.72 ml (P = 0.048, Cohen’s d = – 0.39); Submental region: – 1.26±2.22 ml (95% CI: – 2.118 to – 0.394, P < 0.05, Cohen’s d = – 0.565),with the submental region demonstrating superior durability. The nasolabial fold region, volume, and maximum depth demonstrated the greatest improvement at 3 months (depth reduction: 0.28 ± 0.08 mm, p < 0.001), with ‘wide-short’ morphological subtypes exhibiting superior efficacy compared to ‘narrow-long’ subtypes (P < 0.05). Skin ultrasound collagen intensity showed progressive improvements, peaking at 9 months ( + 10.08 a.u., 95% CI: 7.73-12.44, P < 0.001, Cohen’s d = 1.54) and remained significantly elevated at 12 months with a 9.03 a.u. increase (95% CI: 6.49 to 11.58, P < 0.001, Cohen’s d = 1.38). Treatment induced significant, sustained increases in skin hydration (mean + 50.5-55.8 μS; p < 0.05; Cohen’s d 0.79-1.06) from 30 minutes through 6 months, with effects becoming non-significant at 9 months (+ 36.4 μS) and returning to baseline by 12 months. Transepidermal water loss (TEWL) decreased significantly from 1 month through 9 months, with peak improvement at 6 months (- 3.05 g/m2/h, 95% CI: – 5.39 to – 0.71, P < 0.05, Cohen’s d = – 0.54). GAIS scores peaked at 3 months (physician rating: 3.48 ± 0.48; patient rating: 3.75 ± 0.44) with strong inter-rater correlation (r = 0.728, P < 0.001) and 89.2% of patients willing to undergo retreatment. Adverse events were mild and transient, limited to erythema (67.9%) and edema (28.6%) resolving within one week.

CONCLUSION: MFU facial rejuvenation demonstrated a time-dependent efficacy profile, with peak improvements observed at 3 months and substantial benefits maintained at 9-12 months. Treatment response varied anatomically, showing most durable submental improvement. Nasolabial fold morphological subtypes significantly influenced efficacy, with ‘wide-short’ morphology correlating with superior outcomes. The procedure provided significant rejuvenation with minimal downtime, high patient satisfaction and an excellent safety profile. Level of Evidence III This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 . Trial Registrations This trial is registered with ChiCTR2400093439 (China) and NCT06286384 (ClinicalTrials.gov).

PMID:40931143 | DOI:10.1007/s00266-025-05205-z

Categories
Nevin Manimala Statistics

Letter to the Editor concerning “Evaluating ChatGPT-4.0’s accuracy and potential in idiopathic scoliosis conservative treatment: a preliminary study on clarity, validity, and expert perceptions” by negrini F, et al. (Eur Spine J [2025]: https://doi.org/10.1007/s00586-025-09166-4)

Eur Spine J. 2025 Sep 11. doi: 10.1007/s00586-025-09347-1. Online ahead of print.

NO ABSTRACT

PMID:40931134 | DOI:10.1007/s00586-025-09347-1

Categories
Nevin Manimala Statistics

Comparison of oblique lumbar interbody fusion with pedicle screw fixation versus stress endplate augmentation and anterolateral screw fixation for degenerative lumbar spinal stenosis in osteoporotic patients

Eur Spine J. 2025 Sep 11. doi: 10.1007/s00586-025-09358-y. Online ahead of print.

ABSTRACT

PURPOSE: This study aims to assess the outcomes of combining oblique lumbar interbody fusion (OLIF) with anterolateral screw fixation (ASF) and stress endplate augmentation (SEA) in comparison to OLIF combined with pedicle screw fixation (PSF) for the treatment of degenerative lumbar spinal stenosis (DLSS) in patients with osteoporosis (OP).

METHODS: We performed a retrospective analysis of patients diagnosed with DLSS who underwent OLIF in conjunction with either SEA and ASF (SEA-ASF group) or PSF (PSF group). Clinical outcomes, including the visual analog scale (VAS) scores for lumbar and leg pain, as well as the Oswestry Disability Index (ODI), were assessed at various postoperative intervals and compared to preoperative values. Additionally, radiographic outcomes such as disc height (DH), lumbar lordosis (LL), segmental lordosis (SL), cage subsidence (CS), and fusion rate were evaluated at different postoperative intervals and compared to their preoperative measurements.

RESULTS: A total of 65 patients were enrolled in the study, comprising 30 individuals in the SEA-ASF group and 35 in the PSF group. No statistically significant differences were observed in surgery-related complications between the groups. While VAS and ODI scores did not differ significantly at the 24-month follow-up, the SEA-ASF group exhibited superior scores at both 1 day and 1 month post-surgery (P < 0.05). Significant differences were observed in DH, LL, and SL at both 12 and 24 months postoperatively between the two groups (P < 0.05). At the 24-month postoperative follow-up, the incidence of CS was observed to be 16.67% (5 out of 30) in the SEA-ASF cohort and 11.43% (4 out of 35) in the PSF cohort. Statistical analysis revealed no significant difference between the two groups (P = 0.542). Fusion rates at the 24-month postoperative follow-up were 83.33% (25/30) in the SEA-ASF group and 85.71% (30/35) in the PSF group, also showing no significant difference (P = 0.791).

CONCLUSION: For the management of DLSS patients with osteoporosis, we propose that the integration of OLIF with SEA and ASF constitutes a viable therapeutic option. This approach demonstrates comparable clinical and radiological outcomes to OLIF-PSF, while offering benefits such as reduce operative duration, decrease blood loss, and minimize tissue trauma.

PMID:40931132 | DOI:10.1007/s00586-025-09358-y

Categories
Nevin Manimala Statistics

Changes in food choices and dietary patterns during the lifestyle intervention and their association with type 2 diabetes risk in participants with high or low genetic risk for type 2 diabetes

Eur J Nutr. 2025 Sep 11;64(6):274. doi: 10.1007/s00394-025-03791-x.

ABSTRACT

PURPOSE: To investigate how a group-based lifestyle intervention affects food choices and if the dietary patterns at the end of the intervention are associated with incidence type 2 diabetes (T2D). We also investigated if the possible associations between diet and T2D risk were modified by the genetic risk for T2D.

METHODS: Participants in the T2D-GENE study were men with prediabetes aged 50-75 years, body mass index ≥ 25 kg/m2, belonging in either low or high genetic risk score (GRS) tertile for T2D. They participated in a 3 year, group-based T2D-GENE lifestyle study (either an intervention or a control arm). Food consumption was measured with a food frequency questionnaire (FFQ) at baseline and at year 3. We included in our study all the T2D-GENE participants who had FFQ available at year 3 (n = 883). To diagnose T2D we used the following criteria, fasting plasma glucose ≥ 7.0 mmol/l, 2 h plasma glucose ≥ 11.1 mmol/l, or HbA1C ≥ 48 mmol/mol ( ≥ 6.5%). The GRS was based on 76 genetic variants associated with T2D.

RESULTS: There were statistically significant changes towards more recommended food consumption (higher frequency of whole-grain products, vegetables, and non-tropical vegetable oils) in the participants receiving lifestyle counselling as compared to their baseline and to the population controls. The intervention group reported increased consumption of healthy dietary pattern (high in e.g. vegetables, whole-grain products, and fish) and decreased consumption of unhealthy (high in e.g. meat, sausages and low-fibre products) at year three as compared to baseline. End-of-intervention healthy dietary pattern was associated with a decrease in the risk of T2D (OR 0.67, 95% CI 0.46; 0.97 in multivariable model) and end-of-intervention unhealthy pattern with increased risk (OR 1.82, 95% CI 1.26; 2.62 in multivariable model). When stratified by the GRS, the associations remained significant for the high genetic risk group.

CONCLUSION: A group-based lifestyle intervention improved diet quality. Healthy dietary pattern associated with lower risk for T2D whereas unhealthy pattern associated with higher risk. After stratification by the GRS, associations were evident in participants with a high genetic risk for T2D.

PMID:40931124 | DOI:10.1007/s00394-025-03791-x

Categories
Nevin Manimala Statistics

Dietary lignan intake and body fat distribution in U.S. adolescents

Pediatr Res. 2025 Sep 10. doi: 10.1038/s41390-025-04363-9. Online ahead of print.

ABSTRACT

BACKGROUND: Body fat distribution patterns impact adolescent health, yet research on dietary lignans’ influence remains limited. This study investigated their association among U.S. adolescents.

METHODS: Data from 1579 adolescents (NHANES 2003-2006) were analyzed. Urinary enterolactone and enterodiol concentrations measured dietary lignan intake. Dual-energy X-ray absorptiometry assessed body fat distribution. Survey-weighted linear regression models with progressive adjustment were employed, and restricted cubic spline analyses evaluated potential non-linear relationships.

RESULTS: Urinary enterolactone levels were significantly inversely associated with android-to-gynoid fat ratio (fully adjusted model: β = -0.007, 95% CI: -0.012, -0.002, P = 0.008), indicating a significant negative relationship between enterolactone and android-to-gynoid fat ratio, with restricted cubic spline analysis confirming significant overall association (P for overall = 0.001, demonstrating the statistical significance of the entire relationship) and linear relationship (P for nonlinear = 0.064, indicating the relationship does not significantly deviate from linearity). Further analysis showed that enterodiol was positively associated with gynoid fat ratio (β = 0.360, 95% CI: 0.043, 0.677, P = 0.028), suggesting enterodiol exposure may favor gynoid fat distribution.

CONCLUSION: Dietary lignan intake significantly associates with more favorable body fat distribution patterns among U.S. adolescents, suggesting that increasing dietary lignan intake may be a potential strategy for improving adolescent body composition.

IMPACT: Dietary lignan intake, measured by urinary biomarkers, is significantly associated with favorable body fat distribution patterns in U.S. adolescents. This study highlights the role of dietary lignans, an underexplored dietary component, in influencing body fat distribution during adolescence, expanding on prior research focused on adults. These findings suggest dietary lignans as a potential nutritional strategy to improve body fat distribution in adolescents, offering insights for public health interventions targeting metabolic health in youth.

PMID:40931118 | DOI:10.1038/s41390-025-04363-9

Categories
Nevin Manimala Statistics

Flexible suction-coagulation probe restores dexterity in robot-assisted surgery: bench-to-bedside evaluation

Surg Endosc. 2025 Sep 10. doi: 10.1007/s00464-025-12138-w. Online ahead of print.

ABSTRACT

OBJECTIVE: Rigid suction-coagulation probes constrain the wrist-like articulation that is central to robotic surgery. We therefore designed a 5-mm single-use flexible suction ball coagulator (flex-SBC) with a modified core design to restore dexterity and assessed its mechanical performance and early clinical feasibility, including the effect of the common robotic gripping strategies on suction flow.

METHODS: Preclinical. The new 7 × 7 core embedded in silicone was compared with the conventional 1 × 7 core design. Shaft pliability was quantified by sagging displacement and rebound force testing. Suction flow at – 20, – 30, and – 40 kPa was measured, and the impact of grip location (electrode base vs silicone shaft) and forceps type (fenestrated or Maryland bipolar) was analyzed statistically.

CLINICAL: The flex-SBC was used in 12 consecutive robotic gastrectomies with prospective collection of device performance, adverse events, and surgeon rating on seven-domain via three-point Likert scale.

RESULTS: Preclinical. Adopting the 7 × 7 increased mean sagging displacement from 15.6 ± 1.8 to 39.3 ± 3.2 mm (p < 0.001) and reduced rebound force from 0.288 ± 0.014 to 0.059 ± 0.004 N (p < 0.001). Mean flow rates were 6.76 ± 0.88, 8.87 ± 0.43, and 10.58 ± 0.40 mL/sec at – 20, – 30, and – 40 kPa, respectively-approximately half those of a rigid probe (all p < 0.001) but still exceeding published thresholds for effective evacuation. Gripping the silicone shaft, especially with Maryland forceps, sharply reduced flow (60% reduction; p < 0.0011).

CLINICAL: All operations were completed without device-related malfunctions, injuries, or conversions. Of 84 survey ratings, connection setup, suction efficiency, tissue safety, and overall satisfaction were “satisfactory” in 100%; maneuverability was “satisfactory” in 65% and “average” in 35%. No “unsatisfactory” scores were recorded.

CONCLUSIONS: The flex-SBC bends where the robot bends, enabling safe, practical use across robot-assisted upper-GI surgery. Grip technique influences device performance, providing important implications training. Larger comparative trials should clarify whether these ergonomic gains translate into shorter operating times and improved oncologic precision.

PMID:40931103 | DOI:10.1007/s00464-025-12138-w

Categories
Nevin Manimala Statistics

Performance evaluation of a p-type co-axial HPGe detector: Long-term analysis of key parameters for gamma spectroscopy

Appl Radiat Isot. 2025 Sep 4;226:112161. doi: 10.1016/j.apradiso.2025.112161. Online ahead of print.

ABSTRACT

Accurate determination of the parameters of each high purity germanium, HPGe detectors ensure the precision of quantitative results obtained from spectrum analysis. This study presents a comprehensive performance evaluation and long-term quality control assessment of a high-purity germanium (HPGe) gamma spectrometry system that has been operational for over 15 years. Key spectrometric measures were recorded, including energy resolution, peak shape ratios, asymmetry, peak-to-Compton ratio, relative efficiency, electronic noise, minimum detectable activity (MDA), and repeatability and reproducibility of the system. With the assistance of a calibrated source Co-60, the detector exhibited a commendable energy resolution of 2.01 keV (FWHM), along with good peak shape ratios (FWTM/FWHM = 1.73, FWFM/FWHM = 2.48) and a peak-to-Compton ratio of 52.2, indicating high resolution and zero spectral distortion. Relative detector efficiency was 33.88 % at 1332.5 keV, and electronic noise was negligible at 0.178 %. MDA for certain radionuclides was found to be in the range 0.048-0.605 Bq/kg, which showed good sensitivity even for low-activity peaks. Repeatability tests gave a coefficient of variation (%CV) less than 1 % for all peaks measured, while reproducibility was confirmed with t-test and F-test statistical tests. A Shewhart X‾-control chart revealed that at all times in all cases, measurements were within control limits, though a slight downward trend in the last few years suggests potential need for recalibration or maintenance. The findings corroborate the sustained conformity of the system to ISO/IEC 17025 quality standards and its sufficiency for precise and trustworthy gamma-ray analysis in radionuclide quantification and environmental monitoring.

PMID:40929755 | DOI:10.1016/j.apradiso.2025.112161

Categories
Nevin Manimala Statistics

The effects of missing data due to study dropout on longitudinal analysis inference using outcome-dependent sampling

Int J Epidemiol. 2025 Aug 18;54(5):dyaf150. doi: 10.1093/ije/dyaf150.

ABSTRACT

BACKGROUND: Existing longitudinal cohort study data and associated biospecimen libraries provide abundant opportunities to efficiently examine new hypotheses through retrospective specimen testing. Outcome-dependent sampling (ODS) methods offer a powerful alternative to random sampling when testing all available specimens is not feasible or biospecimen preservation is desired. For repeated binary outcomes, a common ODS approach is to extend the case-control framework to the longitudinal setting.For ODS designs, we consider the impact of incomplete follow-up when missingness is completely at random (MCAR), missing at random (MAR), and missing not at random (MNAR). We further consider sampling from (i) complete cases, in which, in an attempt to maximize power, participants who dropped out before study completion were excluded; and (ii) all individuals, including those with incomplete follow-up.

METHODS: Simulation studies based on the Advancing Clinical Therapeutics Globally HIV Infection, Aging, and Immune Function Long-Term Observational Study cohort were used to examine the impact of MCAR, MAR, and MNAR missingness, assuming specimens were sampled from either (i) complete cases; or (ii) all individuals. Three ODS analytical methods were considered.

RESULTS: When longitudinal data are MNAR, ODS methods exhibit bias similar to that seen in random sampling. MNAR and MAR bias is exacerbated when sampling only participants with complete follow-up. Simulations indicate that ODS analyses that include participants with incomplete follow-up are robust to MCAR and less biased by MAR missingness.

CONCLUSION: Dropout is common in longitudinal cohort studies. Investigators utilizing ODS methods must consider the effect of dropout in both the retrospective sampling design and analysis.

PMID:40929733 | DOI:10.1093/ije/dyaf150

Categories
Nevin Manimala Statistics

Correction: Factors Affecting the Receptiveness of Chinese Internists and Surgeons Toward Artificial Intelligence-Driven Drug Prescription: Protocol for a Systematic Survey Study

JMIR Res Protoc. 2025 Sep 10;14:e83537. doi: 10.2196/83537.

ABSTRACT

[This corrects the article DOI: .].

PMID:40929725 | DOI:10.2196/83537

Categories
Nevin Manimala Statistics

Understanding and Addressing Challenges With Electronic Health Record Use in Gynecological Oncology: Cross-Sectional Survey of Multidisciplinary Professionals in the United Kingdom and Co-Design of an Integrated Informatics Platform to Support Clinical Decision-Making

JMIR Cancer. 2025 Sep 10;11:e58657. doi: 10.2196/58657.

ABSTRACT

BACKGROUND: Electronic health records (EHRs) are a cornerstone of modern health care delivery, but their current configuration often fragments information across systems, impeding timely and effective clinical decision-making. In gynecological oncology, where care involves complex, multidisciplinary coordination, these limitations can significantly impact the quality and efficiency of patient management. Few studies have examined how EHR systems support clinical decision-making from the perspective of end users. This study aimed to explore multiprofessional experiences of EHR use in gynecological oncology and to develop a co-designed informatics platform to improve decision-making for ovarian cancer care.

OBJECTIVE: This study aims to evaluate the perspectives of health care professionals on retrieving routine clinical data from EHRs in the management of ovarian cancer and to design an integrated informatics platform that supports clinical decision-making.

METHODS: We conducted a national cross-sectional survey of 92 UK-based professionals working in gynecological oncology, including oncologists, nurses, radiologists, and other specialists in ovarian cancer. The web-based questionnaire, combining quantitative and free-text responses, assessed their experiences with EHR use, focusing on information retrieval, usability challenges, perceived risks, and benefits. In parallel, a human-centered design approach involving health care professionals, data engineers, and informatics experts codeveloped a digital informatics platform that integrates structured and unstructured data from multiple clinical systems into a unified patient summary view for clinical decision-making. Natural language processing was applied to extract genomic and surgical information from free-text records, with data pipelines validated by clinicians against original clinical system sources.

RESULTS: Among 92 respondents, 84 out of 91 (92%) routinely accessed multiple EHR systems, with 26 out of 91 (29%) using 5 or more. Notably, 16 out of 92 respondents (17%) reported spending more than 50% of their clinical time searching for patient information. Key challenges included lack of interoperability (35/141 reported challenges, 24.8%), difficulty locating critical data such as genetic results (57/85 respondents, 67%), and poor organization of information. Only 10 out of 92 professionals (11%) strongly agreed that their systems provided well-organized data for clinical use. While ease of access to patient data was a key benefit, 54 out of 90 respondents (60%) reported lacking access to comprehensive patient summaries. To address these issues, our co-designed informatics platform consolidates disparate patients’ data from different EHR systems into a single visual display to support clinical decision-making and audit.

CONCLUSIONS: Current EHR systems are suboptimal for supporting complex gynecological oncology care. Our findings highlight the urgent need for integrated, user-centered clinical decision tools. Fragmentation and lack of interoperability hinder information retrieval and may compromise patient care. Our co-designed ovarian cancer informatics platform is a potential real-world solution to improve data visibility, clinical efficiency, and ultimately the quality of ovarian cancer care.

PMID:40929723 | DOI:10.2196/58657