Categories
Nevin Manimala Statistics

Fat distribution measurements by chemical shift-encoded transition region extraction predict the risk of hyperglycaemia, dyslipidaemia and metabolic syndrome in mice

NMR Biomed. 2023 Jun 7:e4985. doi: 10.1002/nbm.4985. Online ahead of print.

ABSTRACT

Metabolically healthy or unhealthy obesity is closely related to metabolic syndrome (MetS). To validate a more accurate diagnostic method for obesity that reflects the risk of metabolic disorders in a pre-clinical mouse model, C57BL/6J mice were fed high-sucrose-high-fat and chow diets for 12 weeks to induce obesity. MRI was performed and analysed by chemical shift-encoded fat-water separation based on the transition region extraction method. Abdominal fat was divided into upper and lower abdominal regions at the horizontal lower border of the liver. Blood samples were collected, and the glucose level, lipid profile, liver function, HbA1c and insulin were tested. k-means clustering and stepwise logistic regression were applied to validate the diagnosis of hyperglycaemia, dyslipidaemia and MetS, and to ascertain the predictive effect of MRI-derived parameters to the metabolic disorders. Pearson or Spearman correlation was used to assess the relationship between MRI-derived parameters and metabolic traits. The receiver-operating characteristic curve was used to evaluate the diagnostic effect of each logistic regression model. A two-sided p value less than 0.05 was considered to indicate statistical significance for all tests. We made the precise diagnosis of obesity, dyslipidaemia, hyperglycaemia and MetS in mice. In all, 14 mice could be diagnosed as having MetS, and the levels of body weight, HbA1c, triglyceride, total cholesterol and low-density lipoprotein cholesterol were significantly higher than in the normal group. Upper abdominal fat better predicted dyslipidaemia (odds ratio, OR = 2.673; area under the receiver-operating characteristic curve, AUCROC = 0.9153) and hyperglycaemia (OR = 2.456; AUCROC = 0.9454), and the abdominal visceral adipose tissue (VAT) was better for predicting MetS risk (OR = 1.187; AUCROC = 0.9619). We identified the predictive effect of fat volume and distribution in dyslipidaemia, hyperglycaemia and MetS. The upper abdominal fat played a better predictive role for the risk of dyslipidaemia and hyperglycaemia, and the abdominal VAT played a better predictive role for the risk of MetS.

PMID:37283179 | DOI:10.1002/nbm.4985

Categories
Nevin Manimala Statistics

Understanding the impact of the COVID‑19 pandemic on healthcare services for adults during three waves of COVID‑19 infections: A South African private sector experience

S Afr Med J. 2023 Mar 8;113(4):e16505. doi: 10.7196/SAMJ.2023.v113i4.16505.

ABSTRACT

BACKGROUND: Since the onset of the COVID‑19 pandemic, healthcare resources have been repurposed to focus on COVID‑19. Resource reallocation and restrictions to movement that affected general access to care may have inadvertently resulted in undue disruptions in the continuum of care for patients requiring non-COVID‑19 healthcare services.

OBJECTIVES: To describe the change in pattern of health service use in the South African (SA) private sector.

METHODS: We conducted a retrospective study of a nationwide cohort of privately insured individuals. An analysis of claims data was performed for non-COVID‑19 related healthcare services provided from April 2020 to December 2020 (year 1 of COVID‑19) and April 2021 to December 2021 (year 2 of COVID‑19) relative to the same period in 2019 prior to the COVID‑19 pandemic in SA. Over and above plotting the monthly trends, we tested for statistical significance of the changes using a Wilcoxon test given the non-normality of all the outcomes.

RESULTS: Between April and December 2020, relative to the same period in 2021, and also relative to the same period in 2019, we found a 31.9% (p<0.01) and a 16.6% (p<0.01) reduction in emergency room visits, respectively; a 35.9% (p<0.01) and 20.5% (p<0.01) reduction in medical hospital admissions; a 27.4% (p=0.01) and 13.0% (p=0.03) reduction in surgical hospital admissions; a 14.5% (p<0.01) and 4.1% (p=0.16) reduction in face-to-face general practitioner consultations for chronic members; a 24.9% (p=0.06) and 5.2% (p=0.54) reduction in mammography for female members; a 23.4% (p=0.03) and 10.8% (p=0.09) reduction in Pap smear screenings for female members; a 16.5% (p=0.08) and 12.1% (p=0.27) reduction in colorectal cancer registrations and an 18.2% (p=0.08) and 8.9% (p=0.07) decrease in all oncology diagnoses. Uptake of telehealth services throughout the healthcare delivery system increased by 5 708% in 2020 compared with 2019, and 36.1% for 2021 compared with 2020.

CONCLUSION: A significant reduction in emergency room visits, hospital admissions and utilisation of primary care services was observed since the start of the pandemic. Further research is required to understand if there are long-term consequences of delayed care. An increase in the use of digital consultations was observed. Research on their acceptability and effectiveness may open new modalities of care, which may have cost- and time-saving benefits.

PMID:37283155 | DOI:10.7196/SAMJ.2023.v113i4.16505

Categories
Nevin Manimala Statistics

Investigating the relationship between breast and gynecological cancers and infertility and its treatments: a case-control study

Eur J Cancer Prev. 2023 May 22. doi: 10.1097/CEJ.0000000000000815. Online ahead of print.

ABSTRACT

OBJECTIVE: Due to the high prevalence of breast and gynecological cancers among women, it is crucial to identify the risk factors of these cancers. Thus, the present study aimed to evaluate the relationship between breast and gynecological cancers and infertility and its treatments in women suffering from these cancers.

METHODS: This case-control study was conducted with the participation of 400 people (200 women with breast and gynecological cancers and 200 healthy women without a history of cancer) in hospitals and health centers in Tabriz, Iran, in 2022. Data were collected using a four-part researcher-made questionnaire including sociodemographic characteristics, obstetric characteristics, information related to cancer, and information related to infertility and its treatments.

RESULT: s Based on the multivariable logistic regression model and by controlling sociodemographic and obstetric characteristics as possible confounding variables, women with cancer had an infertility history almost four times more than women who did not have a history of cancer (OR = 3.56; 95% CI: 1.36-9.33; P = 0.010). Women with breast cancer had an infertility history five times more than women without a history of breast cancer (OR = 5.11; 95% CI: 1.68-15.50; P = 0.004). The infertility history of women with gynecological cancer was more than three times that of the control group. However, there was no statistically significant difference between the two groups (OR = 3.36; 95% CI: 0.99-11.47; P = 0.053).

CONCLUSION: Infertility and its treatments may be involved in increasing the risk of breast and gynecological cancers.

PMID:37283054 | DOI:10.1097/CEJ.0000000000000815

Categories
Nevin Manimala Statistics

Assessment of the Dentinal Surface Adaptation Efficacy of Different Obturation Systems with Bioceramic Sealer: A Scanning Electron Microscope Study

J Contemp Dent Pract. 2022 Aug 1;23(8):834-838. doi: 10.5005/jp-journals-10024-3345.

ABSTRACT

AIM: Aim of this study was to evaluate the dentinal surface adaptation effectiveness of different obturation methods with bioceramic sealer.

MATERIALS AND METHODS: Sixty recently removed human permanent premolars of the mandible having a solitary, straight as well as completely produced root were chosen on the basis of clinical/radiographic evaluation. The coronal parts of the premolars were subjected to sectioning at the cementoenamel junction (CEJ) with the aid of a water-cooled diamond disk. The regular access opening was done, following which the working length was visually estimated by deducting 1 mm from the length of a 10 size K-file (Dentsply, OK, USA) at the apex. Subsequent to preparing the radicular canal, the premolar specimens were randomly allocated to one of the following three groups. Group I: Lateral compaction (LC) technique; group II: Warm vertical compaction (WVC) technique; and group III: Thermafil obturation technique. Following obturation, the samples were subjected to sectioning in the horizontal direction at three dissimilar points as follows: First at the cervical third, then at the middle, and at the apical third employing a minitom under water irrigation to put off overheating. Internal spaces amid the radicular dentin as well as the obturating agents were appraised with the use of a scanning electron microscope (SEM).

RESULTS: Intragroup analysis showed that higher gaps were noted at the coronal level (2.30 ± 0.04), in pursuit by middle part (1.12 ± 0.02) and apical third (0.70 ± 0.02) for the LC method. With the WVC procedure, higher gaps were situated in the coronal level (1.96 ± 0.07), again in pursuit by middle part (1.02 ± 0.02) and apical third (0.86 ± 0.04). Even with the Thermafil obturation method, higher gaps were noted at the coronal level (0.92 ± 0.10), in pursuit by middle part (0.67 ± 0.05) and apical third (0.57 ± 0.01). No statistically significant difference was noted within the group. Upon intergroup comparative assessment of dentinal surface adaptation with dissimilar obturation systems at coronal, middle and apical thirds, there was a statistically noteworthy disparity amid the groups (p <0.001).

CONCLUSION: This research arrived at a conclusion that the most superior dentinal adaptation of bioceramic sealer was procured when the Thermafil obturation method was employed for obturating the root canals compared to the WVC technique as well as the LC technique.

CLINICAL SIGNIFICANCE: Numerous endodontic substances have been promoted for obturating the root canal areas. Majority of the methods use a core substance, in addition to a sealer. Despite the type of core agent, a sealer indispensable to each technique offers a fluid-tight sealing. The oral physicians’ comprehension of the characteristics of the endodontic sealer plus method used, enhances the therapeutic effect.

PMID:37283019 | DOI:10.5005/jp-journals-10024-3345

Categories
Nevin Manimala Statistics

Quantitative Analysis of Publication Trends in the Journal of Indian Prosthodontic Society between 2011 and 2020

J Contemp Dent Pract. 2022 Aug 1;23(8):828-833. doi: 10.5005/jp-journals-10024-3390.

ABSTRACT

AIM: To analyze quantitatively the trends in publication and compare the scientific content published during 2011-2015 and 2016-2020.

MATERIALS AND METHODS: An online search for all the different manuscripts published from 2011 to 2020 was performed electronically on the website of the Journal of Indian Prosthodontic Society (JIPS). The manuscripts were grouped into the following broader categories: Author, article grouping, original article subtype, prosthetic division, and statistical analysis.

RESULTS: The authors from private institutions showed higher publication trends than the authors from government institutions. The period 2016-2020 showed a higher number of publications with four or more authors. There was more original research published, followed by case reports. There was an increasing trend in a systematic review during 2016-2020 as compared to the period 2011-2015. There were a greater number of in vitro experimental studies published with a comparison of the means in the statistical analysis. There was more publication on materials and technology, followed by implants in the prosthetic division of articles.

CONCLUSION: The analysis shows the overall progress of the journal explains the characteristics of the authors involved in the research, highlights the types of research done, statistical methods used, and important areas of research and trends in research in prosthodontics at a national level.

CLINICAL SIGNIFICANCE: The publication trends will focus on the research thrust areas and the type of research done in the specialty, pointing out the gaps in the research and identifying the future course of action for authors and journals. It also helps for comparison with international publication trends in prosthodontics and provides information to prospective authors to focus research on the priority areas of the concerned journal for better acceptance.

PMID:37283018 | DOI:10.5005/jp-journals-10024-3390

Categories
Nevin Manimala Statistics

Impact of Three Different Surgical Drilling Protocols on Early Loaded Single Implant in Posterior Maxilla: A 3-year Follow-up

J Contemp Dent Pract. 2022 Aug 1;23(8):819-827. doi: 10.5005/jp-journals-10024-3391.

ABSTRACT

AIM: This study aims to compare three different drilling techniques for implant site preparation to enhance the primary stability of the early loaded single implant in the posterior maxilla.

MATERIALS AND METHODS: A total of 36 dental implants were used in this study for the replacement of a missing single tooth or more in the maxillary posterior region with an early loaded dental implant. The patients were randomly divided into three groups. In group I, the drilling was performed using an undersized drilling technique, in group II, the drilling was performed using bone expanders, and in group III, the drilling was performed using the osseodensification (OD) technique. Patients were evaluated clinically and radiographically at regular time intervals immediately, 4 weeks, 6 months, 1 year, 2 years, and 3 years after surgery. All clinical and radiographic parameters were subjected to statistical analysis.

RESULTS: All implants in group I were stable and successful, while 11 from 12 implants survived in both groups II and III. There was no significant difference in peri-implant soft tissue health and marginal bone loss (MBL) throughout the whole study period between the three groups, while there was a significant difference in implant stability and insertion torque between groups I, II, and III at the time of implant placement.

CONCLUSION: Preparing the implant bed using the undersized drilling technique with drills with similar geometry to the implant being inserted provides high implant primary stability without the need for additional instruments or cost.

CLINICAL SIGNIFICANCE: Dental implants can be early loaded in the posterior maxilla by using an undersized drilling technique, as it improves primary stability.

PMID:37283017 | DOI:10.5005/jp-journals-10024-3391

Categories
Nevin Manimala Statistics

Quantitative Microbial Leakage Evaluation of Restorative Materials with/without Antibacterial Primer as an Intracoronal Barrier: An Ex Vivo Study

J Contemp Dent Pract. 2022 Aug 1;23(8):813-818. doi: 10.5005/jp-journals-10024-3357.

ABSTRACT

AIM: Aim of this research was to assess the microbial leakage of restorative materials with/without antibacterial primer as an intracoronal barrier.

MATERIALS AND METHODS: Fifty-five extracted single-rooted teeth were included in this study. The canals were cleaned, shaped, and obturated with gutta-percha and AH plus sealer at the established working length. After removing 2 mm of coronal gutta-percha, the teeth were incubated for 24 hours. The teeth were divided into groups according to the materials used as intracoronary orifice barriers as follows: • Group I: Clearfil Protect Bond/Clearfil AP-X • Group II: Xeno IV/Clearfil AP-X • Group III: Chemflex (glass ionomer) • Group IV: Positive control (no barrier) • Group V: Negative control (no barrier and inoculated with sterile broth) Sterile 2 chambers bacterial technique was used to assess the microleakage and Enterococcus faecalis was considered as a microbial marker. The percentage of samples leaked, the time taken for leakage, and the number of colony-forming units (CFUs) in the leaked samples were calculated and analyzed statistically.

RESULTS: There was no statistically significant difference found in bacterial penetration among the three investigated materials after 120 days of use as an intracoronal orifice barrier. This study can also infer that the leaked sample from the Clearfil Protect Bond showed the least mean number of CFUs (43 CFUs) followed by Xeno IV (61 CFUs) and glass ionomer cement (GIC) (63 CFUs).

CONCLUSION: This study concluded that all three experimental antibacterial primers performed better as intracoronal barrier. However, Clearfil Protect Bond with an antibacterial primer showed promising results as an intracoronal orifice barrier in reducing the number of bacterial leakages.

CLINICAL SIGNIFICANCE: The significance of intracoronal orifice barriers in the success of endodontic treatment depends on the ability of the materials to prevent microleakage. This helps clinicians to provide successful antibacterial therapy against endodontic anaerobes.

PMID:37283016 | DOI:10.5005/jp-journals-10024-3357

Categories
Nevin Manimala Statistics

Influence of Thermocycling and Surface Treatments on the Flexural Strength of Denture Base Resin: An In Vitro Study

J Contemp Dent Pract. 2022 Aug 1;23(8):788-792. doi: 10.5005/jp-journals-10024-3387.

ABSTRACT

AIM: The purpose of this study was to evaluate the flexural strength of heat polymerized denture base resin after thermocycling and different surface treatments done prior to repair or relining.

MATERIALS AND METHODS: In this in vitro study, 80 specimens were made with heat-polymerized denture base resin and thermocycled (500 cycles between 5 and 55 °C). The specimens were divided in four groups based on different types of surface treatment: group I (control group: without surface treatment), group II (chloroform for 30 seconds), group III [methyl methacrylate (MMA) for 180 seconds], and group IV (dichloromethane for 15 seconds). The flexural strength was assessed using a Universal testing machine with three-point bending test. The obtained data were subjected to statistical analysis using one-way ANOVA and post-hoc tests.

RESULTS: The values of average flexural strength of denture base resin measured were as follows: group I: 111.1 MPa, group II: 86.9 MPa, group III: 73.1 MPa, and group IV: 78.8 MPa. Groups II and IV possessed superior flexural strength than group III. The maximum values were observed with the control group.

CONCLUSION: The flexural strength of heat-polymerized denture base resin gets affected by different surface treatments done prior to relining procedures. Lowest flexural strength was obtained when treated with MMA monomer for 180 seconds as compared to the other etchants used.

CLINICAL SIGNIFICANCE: Prior to denture repair procedures, operators must choose the chemical surface treatment judiciously. It should not affect the mechanical properties such as flexural strength of denture base resins. Reduction in flexural strength of polymethyl methacrylate (PMMA) denture base can predispose the prosthesis to deteriorated performance when in function.

PMID:37283012 | DOI:10.5005/jp-journals-10024-3387

Categories
Nevin Manimala Statistics

Effect of Frequency of Micro-osteoperforation on Miniscrew- supported Canine Retraction: A Single-centered, Split-mouth Randomized Controlled Trial

J Contemp Dent Pract. 2022 Aug 1;23(8):781-787. doi: 10.5005/jp-journals-10024-3385.

ABSTRACT

AIM: The present study aimed at evaluating the increase in the rate of tooth movement by increasing the number and frequency of micro-osteoperforations (MOPs).

MATERIALS AND METHODS: The study was a single-center, split-mouth, randomized controlled trial. A total of 20 patients were included in the study who had fully erupted maxillary canines with class I molar canine relationship and a bimaxillary protrusion that required the removal of both maxillary and mandibular first premolars. Out of 80 samples, the experimental and controlled groups were randomly assigned. The experimental group received five MOPs in the extracted site of the first premolar before retraction, at 28th day and 56th day. The control group received no MOPs. The rate of tooth movement was measured on 28th, 56th, and 84th day on both the experimental and control sides.

RESULTS: In maxillary dentition, the canine on the MOP side moved by 0.65 ± 0.21 mm, 0.74 ± 0.23 mm, and 0.87 ± 0.27 mm during 28th, 56th, and 84th day, respectively, whereas in control side the rate of tooth movement was 0.37 ± 0.09 mm, 0.43 ± 0.11 mm, and 0.47 ± 0.11 mm during 28th, 56th and 84th day, respectively, which was statistically significant (p-value = 0.000). In mandibular dentition, the canine on the MOP site has moved by 0.57 ± 0.12 mm, 0.68 ± 0.21 mm, and 0.67 ± 0.10 mm during 28th, 56th, and 84th day, respectively, whereas in control side the rate of the tooth movement was 0.34 ± 0.08 mm, 0.40 ± 0.15 mm, and 0.40 ± 0.13 mm during 28th, 56th, and 84th day, respectively, which was statistically significant.

CONCLUSION: Micro-osteoperforations effectively increased the rate of tooth movement. Overall, MOPs increased the rate of canine retraction by 2-fold when compared with the control group.

CLINICAL SIGNIFICANCE: Micro-osteoperforation is a proven methodology to increase the rate of tooth movement and decrease the treatment time. However, it is important to repeat the procedure during every activation to increase its effectiveness.

PMID:37283011 | DOI:10.5005/jp-journals-10024-3385

Categories
Nevin Manimala Statistics

Effect of Different Light-tip Distances on Shear Bond Strength of Orthodontic Brackets Cured with Light-emitting Diode and High-intensity Light-emitting Diode

J Contemp Dent Pract. 2022 Aug 1;23(8):775-780. doi: 10.5005/jp-journals-10024-3394.

ABSTRACT

AIM: The aim was to find out whether the light-tip distance affected the shear bond strength of orthodontic brackets when cured with light-emitting diode (LED) and high-intensity LED at four different light-tip distances.

MATERIALS AND METHODS: Extracted human premolars were divided into eight groups. Each tooth was embedded in the self-cure acrylic resin block, and brackets were bonded and cured with different lights and different distances. Shear bond strength tests were performed in vitro using the universal testing machine. Data were analyzed using one-way ANOVA test.

RESULTS: The descriptive statistics for shear bond strength of orthodontic brackets cured with LED light at 0 mm was 8.49 ± 1.08 MPa, at 3 mm was 8.13 ± 0.85 MPa, 6 mm was 6.42 ± 0.42 MPa, and at 9 mm was 5.24 ± 0.92 MPa, and those cured with high-intensity light at 0 mm was 19.23 ± 4.83 MPa, at 3 mm was 17.65 ± 3.28 MPa, at 6 mm was 13.04 ± 2.36 MPa, and at 9 mm was 11.74 ± 1.4 MPa. Mean shear bond strength was found to decrease as the light-tip distance increased with both light sources.

CONCLUSION: Shear bond strength is higher when the light source is close to the surface to be cured, and it decreases as the distance increases. The highest shear bond strength was achieved with high-intensity light.

CLINICAL SIGNIFICANCE: Light-emitting diode or high-intensity units can be used for bonding orthodontic brackets without compromising the shear bond strength of the brackets, and that shear bond strength is stronger when the light source is close to the surface to be cured, and it decreases as the distance increases between the light source and the surface.

PMID:37283010 | DOI:10.5005/jp-journals-10024-3394