Categories
Nevin Manimala Statistics

A unified analysis of convex and non‑convex 𝓛p‑ball projection problems

Optim Lett. 2023 Jun;17(5):1133-1159. doi: 10.1007/s11590-022-01919-0. Epub 2022 Sep 4.

ABSTRACT

The task of projecting onto p norm balls is ubiquitous in statistics and machine learning, yet the availability of actionable algorithms for doing so is largely limited to the special cases of p{0, 1, 2, }. In this paper, we introduce novel, scalable methods for projecting onto the p-ball for general p>0. For p1, we solve the univariate Lagrangian dual via a dual Newton method. We then carefully design a bisection approach For p<1, presenting theoretical and empirical evidence of zero or a small duality gap in the non-convex case. The success of our contributions is thoroughly assessed empirically, and applied to large-scale regularized multi-task learning and compressed sensing. The code implementing our methods is publicly available on Github.

PMID:38516636 | PMC:PMC10956251 | DOI:10.1007/s11590-022-01919-0

Categories
Nevin Manimala Statistics

Three-dimensional topology-based analysis segments volumetric and spatiotemporal fluorescence microscopy

Biol Imaging. 2023 Dec 14;4:e1. doi: 10.1017/S2633903X23000260. eCollection 2024.

ABSTRACT

Image analysis techniques provide objective and reproducible statistics for interpreting microscopy data. At higher dimensions, three-dimensional (3D) volumetric and spatiotemporal data highlight additional properties and behaviors beyond the static 2D focal plane. However, increased dimensionality carries increased complexity, and existing techniques for general segmentation of 3D data are either primitive, or highly specialized to specific biological structures. Borrowing from the principles of 2D topological data analysis (TDA), we formulate a 3D segmentation algorithm that implements persistent homology to identify variations in image intensity. From this, we derive two separate variants applicable to spatial and spatiotemporal data, respectively. We demonstrate that this analysis yields both sensitive and specific results on simulated data and can distinguish prominent biological structures in fluorescence microscopy images, regardless of their shape. Furthermore, we highlight the efficacy of temporal TDA in tracking cell lineage and the frequency of cell and organelle replication.

PMID:38516632 | PMC:PMC10951800 | DOI:10.1017/S2633903X23000260

Categories
Nevin Manimala Statistics

Extended correlation functions for spatial analysis of multiplex imaging data

Biol Imaging. 2024 Feb 15;4:e2. doi: 10.1017/S2633903X24000011. eCollection 2024.

ABSTRACT

Imaging platforms for generating highly multiplexed histological images are being continually developed and improved. Significant improvements have also been made in the accuracy of methods for automated cell segmentation and classification. However, less attention has focused on the quantification and analysis of the resulting point clouds, which describe the spatial coordinates of individual cells. We focus here on a particular spatial statistical method, the cross-pair correlation function (cross-PCF), which can identify positive and negative spatial correlation between cells across a range of length scales. However, limitations of the cross-PCF hinder its widespread application to multiplexed histology. For example, it can only consider relations between pairs of cells, and cells must be classified using discrete categorical labels (rather than labeling continuous labels such as stain intensity). In this paper, we present three extensions to the cross-PCF which address these limitations and permit more detailed analysis of multiplex images: topographical correlation maps can visualize local clustering and exclusion between cells; neighbourhood correlation functions can identify colocalization of two or more cell types; and weighted-PCFs describe spatial correlation between points with continuous (rather than discrete) labels. We apply the extended PCFs to synthetic and biological datasets in order to demonstrate the insight that they can generate.

PMID:38516631 | PMC:PMC10951806 | DOI:10.1017/S2633903X24000011

Categories
Nevin Manimala Statistics

The Effect of Modified Framework Design on the Fracture Resistance of IPS e.max Press Crown after Thermocycling and Cyclic Loading

J Contemp Dent Pract. 2024 Jan 1;25(1):79-84. doi: 10.5005/jp-journals-10024-3621.

ABSTRACT

AIM: This study aimed to investigate the effect of modified framework (MF) design on the fracture resistance of IPS e.max Press anterior single crown after thermocycling and cyclic loading.

MATERIALS AND METHODS: Two types of IPS e.max Press frameworks were designed (n = 10); standard framework (SF) with a 0.5 mm uniform thickness and MF with a lingual margin of 1 mm in thickness and 2 mm in height connected to a proximal strut of 4 mm height and a 0.3 mm wide facial collar. The crowns were cemented to resin dies, subjected to 5,000 cycles of thermocycling, and loaded 10,000 cycles at 100 N. A universal testing machine was used to load specimens to fracture, and the modes of failure were determined.

RESULTS: The mean and standard deviation (SD) of fracture resistance were 219.24 ± 110.00 N and 216.54 ±120.02 N in the SF and MF groups. Thus, there was no significant difference (p = 0.96). Mixed fracture was the most common failure mode in both groups. We found no statistically significant difference between the groups (p = 0.58).

CONCLUSION: The MF design did not increase the fracture resistance of IPS e.max Press crown.

CLINICAL SIGNIFICANCE: Framework design is an essential factor for the success of all-ceramic restorations and its modification might be regarded as an approach to increase fracture resistance. Furthermore, the modified design was evaluated in metal-ceramic or zirconia crowns while less attention was paid to the IPS e.max Press crowns. How to cite this article: Golrezaei M, Mahgoli HA, Yaghoobi N, et al. The Effect of Modified Framework Design on the Fracture Resistance of IPS e.max Press Crown after Thermocycling and Cyclic Loading. J Contemp Dent Pract 2024;25(1):79-84.

PMID:38514436 | DOI:10.5005/jp-journals-10024-3621

Categories
Nevin Manimala Statistics

Removal Efficiency and Effectiveness of Four Different Fiber Posts Using Five Different Drill Systems in Multirooted Teeth

J Contemp Dent Pract. 2024 Jan 1;25(1):72-78. doi: 10.5005/jp-journals-10024-3629.

ABSTRACT

AIM: In comparing the effectiveness and efficiency of different types of post removal systems in removing different types of fiber posts (FPs), this study aims to shed light on the success of removal by currently available drill systems.

MATERIALS AND METHODS: A total of 200 maxillary first molars, were root canal treated and prepared to receive posts. The molars were divided into four groups corresponding to four different FPs: Group RX, Radix FP; Group RF, Reforpost Glass Fiber; Group HI; Hi-Rem Endodontic Post; and Group DT, D.T. Light-Post Illusion X-RO. Fiber posts were done with luting by Gradia Core (GC America, Inc.). Groups were again divided into five subgroups corresponding to the technique by which the FP was removed into as follows: Subgroup P, PD-25-1.1 Drill; subgroup G, GC FP Drill; subgroup E, EasyPost Precision Drill; subgroup R, Reaccess Carbide Double Taper Kit; and subgroup H; H-Endodontic Drill. After posts were removed, effectiveness and efficiency were documented. Data were tabulated and statistically analyzed.

RESULTS: Strong significant differences regarding efficiency among groups (FP type) and subgroups (drills used) (p = 0.00) were shown by the one-way analysis of variance (ANOVA) test. Subgroup DT-G scored the longest mean removal time (20.9 minutes) while Subgroup RX-R scored the shortest mean removal time (1.4 minutes) Regarding effectiveness, strong significant differences among groups (p = 0.00) and subgroups (p = 0.00) were shown by one-way ANOVA. Subgroup RF-G scored the highest scale (5.2) whereas subgroup HI-R scored the lowest mean scale (1.2).

CONCLUSION: The difference was strongly significant between tested post-removal kits and between tested FPs. Re-access Carbide Double Taper Kit performed superiorly in both effectiveness and efficiency, followed by PD-25-1.1 Drill. Hi-Rem post showed the best retrieving results among other FPs.

CLINICAL SIGNIFICANCE: Knowing the best technique and tools for post removal could spare the practitioner any unwanted complications during post removal. How to cite this article: Sayed M, Alahmad AM, Alhajji KS, et al. Removal Efficiency and Effectiveness of Four Different Fiber Posts Using Five Different Drill Systems in Multirooted Teeth. J Contemp Dent Pract 2024;25(1):72-78.

PMID:38514435 | DOI:10.5005/jp-journals-10024-3629

Categories
Nevin Manimala Statistics

Medical and Dental Professions’ Varying Levels of Awareness Regarding Medication-related Osteonecrosis of the Jaw in Saudi Arabia? A Cross-sectional Study

J Contemp Dent Pract. 2024 Jan 1;25(1):62-67. doi: 10.5005/jp-journals-10024-3622.

ABSTRACT

AIMS: This study aimed to assess the awareness of the risk of medication-related osteonecrosis of the jaw (MRONJ) among general dental practitioners (GDPs) and primary care physicians (PCPs), focusing on the clinical implications and coordination of treating or identifying high-risk patients.

MATERIALS AND METHODS: Two Google Forms electronic questionnaires were distributed to 724 GDPs and 617 PCPs in primary care settings. One for PCPs with eight multiple choice questions and the other for GDPs with 10 multiple choice questions. A clinical case scenario and a section on open-ended comments were included in both questionnaires. The data obtained from each group were statistically analyzed and compared.

RESULTS: A total of 239 GDPs and 220 PCPs participated in the study, with a response rate of 34.23%. The mean age of participants was 29.5 years and 54.35% were females (51.2% and 57.5% in the GDPs and PCPs group, respectively). Most participants had graduated from Saudi Arabia. Almost all dentists were aware of osteonecrosis of the jaw (95.1%), 68.3% of them were aware of the guidelines regarding bisphosphonate-related osteonecrosis of the jaw (BRONJ) and MRONJ, 60.5% rated their general knowledge about MRONJ as very poor to poor, and 91.8% did not know any guidelines regarding BRONJ or MRONJ. Among the participants, 75.3% did not know how MRONJ was present in the oral cavity. A total of 69.9% of participants were unaware of other factors associated with an increased risk of MRONJ.

CONCLUSION: MRONJ risk awareness varies greatly between dentists who diagnose and manage patients in dental clinics and physicians who write about medicines and therapies. Counseling sessions and greater coordination between dental and medical specialists are strongly suggested while prescribing antiresorptive drugs to prevent the consequent development of MRONJ.

CLINICAL SIGNIFICANCE: This study shows a significant lack of knowledge regarding MRONJ among GDPs and PCPs, which may affect the prevention and treatment of patients. Therefore, we urge GDPS and PCPs to take more information from scientific sources on this topic and more cooperation from specialties for the benefit of patients. How to cite this article: Aljohani MH, Aljohani AS, Aljohani RM, et al. Medical and Dental Professions’ Varying Levels of Awareness Regarding Medication-related Osteonecrosis of the Jaw in Saudi Arabia? A Cross-sectional Study. J Contemp Dent Pract 2024;25(1):62-67.

PMID:38514433 | DOI:10.5005/jp-journals-10024-3622

Categories
Nevin Manimala Statistics

Comparative Assessment of Marginal Micro Leakage of Different Esthetic Restorative Materials Used on Primary Teeth: An In-vitro Study

J Contemp Dent Pract. 2024 Jan 1;25(1):58-61. doi: 10.5005/jp-journals-10024-3595.

ABSTRACT

AIM: The aim of the current investigation was to evaluate the marginal microleakage of various esthetic restorative materials applied to primary teeth.

MATERIALS AND METHODS: A total of 75 noncarious primary molars that were removed for orthodontic intervention and teeth nearing exfoliation were chosen. One millimeter (mm) above the cementoenamel junction, on the buccal surface of the teeth, Class V cavities were prepared. William’s graded periodontal probe was used to standardize cavity preparation on all teeth. 3 mm was the cavity’s length, 2 mm in width, and 2 mm in depth. The teeth were then divided into three groups (25 samples in each group) according to the type of esthetic restorative material used. Group I: Resin-modified glass ionomer cement, Group II: Ormocer, Group III: Giomer. The samples underwent 500 cycles of thermocycling, with an immersion time of 60 seconds and a well time of 15 seconds, between 5 and 55°C. The samples were submerged in methylene blue dye for 24 hours at room temperature and dried. The samples were then divided into sections and examined with a stereomicroscope. Data was recorded and statistically analyzed.

RESULTS: The least marginal microleakage was found in the ormocer group (1.22 ± 0.01) followed by resin-modified glass ionomer cement group (1.31 ± 0.07) and the giomer group (1.78 ± 0.03). There was a highly statistically significant difference found between resin-modified glass ionomer cement group and the ormocer group, resin-modified glass ionomer cement group and giomer group. And no significant difference was found between the ormocer group and the giomer group.

CONCLUSION: The present study concluded that there was some amount of microleakage in primary teeth in all restorative materials examined in this in-vitro investigation. However, the marginal sealing ability of ormocer was found highest compared to resin-modified glass ionomer cement and Giomer materials.

CLINICAL SIGNIFICANCE: The primary reason dental restorations fail, particularly in Class V cavities, is microleakage since the margins of these restorations are typically found in the dentin or cementum. Assessing microleakage is a crucial step in determining the marginal integrity of restorative materials. Developing methods and resources that reduce the adverse effects caused by the restorative marginal seal failing would benefit from this. How to cite this article: Al Ghwainem A, Alqarni AS. Comparative Assessment of Marginal Micro Leakage of Different Esthetic Restorative Materials Used on Primary Teeth: An In-vitro Study. J Contemp Dent Pract 2024;25(1):58-61.

PMID:38514432 | DOI:10.5005/jp-journals-10024-3595

Categories
Nevin Manimala Statistics

Combined Effects of Glutaraldehyde-based Desensitizer and Nd: YAG Laser on Dentinal Tubules Occlusion

J Contemp Dent Pract. 2024 Jan 1;25(1):52-57. doi: 10.5005/jp-journals-10024-3623.

ABSTRACT

AIM: The aim of this study was to assess the impact of Nd:YAG laser, glutaraldehyde-based desensitizer (GD), or their combination on occluding dentinal tubules.

MATERIALS AND METHODS: Fifty dentin samples were obtained from non-carious human third molars and randomly divided into five groups (n = 10): (1) Control group treated with 37% phosphoric acid, (2) GD group, (3) Nd:YAG laser group (1064 nm, 100 µs, 10 Hz, 300 µm fiber, 1 W power, 100 mJ energy, and 85 J/cm2 energy density), (4) GD followed by Nd:YAG laser group, and (5) Nd:YAG laser followed by GD group. Scanning electron microscopy (SEM) was used to capture five images from each sample for analysis of dentinal tubules using Image J software. SEM/EDX elemental analysis was performed to determine the main mineral contents. Data analyzed using one-way ANOVA and Tukey’s post hoc test for statistical comparisons.

RESULTS: Laser and combination groups showed a significant decrease in dentinal tubule counts compared with the control and GD groups (p < 0.0001). There were no significant differences in open dentinal tubule counts between the control and GD groups, as well as between the laser and combination groups. However, significant differences were observed in the total area, average size of the tubules, and percentage area between the control group and the treatment groups (GD, laser, GD + laser, laser + GD). No significant difference was found in the Ca/P ratio between the tested groups.

CONCLUSION: The use of Nd:YAG laser alone or in combination with GD was more effective in occluding dentinal tubules compared to GD alone.

CLINICAL SIGNIFICANCE: This study has shown that Nd:YAG laser alone and in combination with GD has superior dentinal tubule occlusion in vitro. Its clinical use in the treatment of dentinal hypersensitivity may overcome the drawback of conventional treatment approaches for dentin hypersensitivity needing repeated applications to achieve continuous relief from pain since acidic diet and toothbrushing result in the continuing elimination of precipitates and surface coatings. How to cite this article: Alzarooni AH, El-Damanhoury HM, Aravind SS, et al. Combined Effects of Glutaraldehyde-based Desensitizer and Nd: YAG Laser on Dentinal Tubules Occlusion. J Contemp Dent Pract 2024;25(1):52-57.

PMID:38514431 | DOI:10.5005/jp-journals-10024-3623

Categories
Nevin Manimala Statistics

Correlating Frictional Forces Generated by Different Bracket Types during Sliding and Surface Topography Using Scanning Electron Microscopy and Optical Profilometer

J Contemp Dent Pract. 2024 Jan 1;25(1):41-51. doi: 10.5005/jp-journals-10024-3625.

ABSTRACT

AIM: The study aims to correlate the frictional forces (FF) of four different types of commercially available ceramic brackets to their surface topography.

MATERIALS AND METHODS: Two monocrystalline (MC) brackets (CLEAR™, Adanta, Germany; Inspire ICE™, Ormco, USA), one polycrystalline (PC) bracket (Symetri Clear™, Ormco, USA), one clear hybrid esthetic bracket (DISCREET™, Adanta, Germany), and a stainless-steel (SS) bracket (Victory™, 3M Unitek, USA) served as control. Both static friction (SF) and kinetic friction (KF) were recorded during sliding using an Instron universal machine in dry settings. The bracket slot surface topography was evaluated. A scanning electron microscope (SEM) and a profilometer machine were used for assessment before and after sliding.

RESULTS: Frictional forces values during sliding were as follows in descending order; Inspire ICE™, CLEAR™, DISCREET™, Symetri Clear™, and, lastly, Victory™. Also, DISCREET™ scored the highest in surface roughness (Sa) values followed by Symetri Clear™. None of the correlations were statistically significant.

CONCLUSION: Frictional forces produced during sliding were not always directly related to surface roughness. Monocrystalline ceramic brackets appeared to have the greatest FF and a low surface roughness. Furthermore, DISCREET™ scored a very low frictional value comparable to metal brackets yet showed the highest surface roughness. Metal brackets exhibited the greatest surface smoothness before sliding and the least SF.

CLINICAL SIGNIFICANCE: Predicting the FFs produced during sliding mechanics would help the practitioner while choosing the bracket system to be used, and while planning the treatment mechanics, how much force to deliver, and how much tooth movement to expect. How to cite this article: AlBadr AH, Talic NF. Correlating Frictional Forces Generated by Different Bracket Types during Sliding and Surface Topography Using Scanning Electron Microscopy and Optical Profilometer. J Contemp Dent Pract 2024;25(1):41-51.

PMID:38514430 | DOI:10.5005/jp-journals-10024-3625

Categories
Nevin Manimala Statistics

Comparative Evaluation of Shear Bond Strength of Resin-modified Glass Ionomer Cement with ProRoot MTA and MTA Angelus

J Contemp Dent Pract. 2024 Jan 1;25(1):35-40. doi: 10.5005/jp-journals-10024-3611.

ABSTRACT

AIM: The aim of the present study was to evaluate the shear bond strength of resin-modified glass ionomer cement with two different types of mineral trioxide aggregate at different time intervals.

MATERIALS AND METHODS: A total of 80 cylindrical blocks were prepared using a self-cure acrylic resin with a central cavity of 4 mm internal diameter and 2 mm height. The prepared samples were randomly divided into two groups (n = 40 each) according to the type of MTA cements used (ProRoot MTA and MTA Angelus). Two groups were further sub-divided into four sub-groups of 10 samples each according to the different time intervals. ProRoot MTA and MTA Angelus were placed in the prepared cavity and a wet cotton pellet was placed over the filled cavity. A hollow plastic tube was placed over the MTA surface and resin-modified glass ionomer cement (RMGIC) was placed into the hollow plastic tube and light-cured (Spectrum 800, Dentsply Caulk Milford, DE, USA) according to the time intervals decided. After light curing the plastic tubes were removed carefully and the specimens were stored at 37°C and 100% humidity for 24 hours to encourage setting of MTA. The specimens were mounted in a universal testing machine (ADMET) and a crosshead speed of 0.5 mm/min was applied to each specimen by using a knife-edge blade until the bond between the MTA and RMGIC failed. The data were statistically analyzed using ANOVA, post hoc Tukey’s t-test and Fisher’s t-test and p-value ≤ 0.5 was considered significant.

RESULTS: For both ProRoot MTA and MTA Angelus there was no statistically significant difference between 45 minutes and 24 hours (p-value ≥ 0.8). For ProRoot MTA, shear bond strength value at 10 minutes were significantly lower than 45 minutes and 24 hours group. However, for MTA Angelus, shear bond strength value at 10 minute was not significantly different from 45 minutes group (p-value ≥ 0.3). For both ProRoot MTA and MTA Angelus shear bond strength value at 0 minute were the least and were significantly lower than 10 minutes, 45 minutes, and 24 hours, respectively (p-value ≥ 0.000).

CONCLUSION: Resin-modified glass ionomer cement can be layered over MTA Angelus after it is allowed to set for 10 minutes. However, ProRoot MTA should be allowed to set for at least 45 minutes before the placement of RMGIC to achieve better shear bond strength.

CLINICAL SIGNIFICANCE: Due to the variety of types of mineral trioxide aggregate cements available in dentistry, it is justifiable to emphasize on different time intervals as it may affect the shear bond strength of restorative cements. Such information is pivotal for the clinicians while using mineral aggregate-based cements that receive forces from the condensation of restorative materials or occlusion, as the compressive strength may be affected due to different time intervals. How to cite this article: Tyagi N, Chaman C, Anand S, et al. Comparative Evaluation of Shear Bond Strength of Resin-modified Glass Ionomer Cement with ProRoot MTA and MTA Angelus. J Contemp Dent Pract 2024;25(1):35-40.

PMID:38514429 | DOI:10.5005/jp-journals-10024-3611