The use of oxygen hoods in patients failing on conventional high-flow oxygen delivery systems, the effects on oxygenation, mechanical ventilation and mortality rates in hypoxic patients with COVID-19. A Prospective Controlled Cohort Study

Respir Med. 2021 Feb 12;179:106312. doi: 10.1016/j.rmed.2021.106312. Online ahead of print.

ABSTRACT

INTRODUCTION: Efforts to meet increased oxygen demands in COVID-19 patients are a priority in averting mechanical ventilation (MV), associated with high mortality approaching 76.4-97.2%. Novel methods of oxygen delivery could mitigate that risk. Oxygen hoods/helmets may improve: O2-saturation (SaO2), reduce in-hospital mechanical ventilation and mortality rates, and reduce length of hospitalization in hypoxic Covid-19 patients failing on conventional high-flow oxygen delivery systems.

METHODS: DesignProspective Controlled Cohort Study. SettingSingle Center. ParticipantsAll patients admitted with a diagnosis of COVID-19 were reviewed and 136/347 patients met inclusion criteria. Study period3/6/2020 to 5/1/2020. 136 participants completed the study with known status for all outcome measures. Intervention or exposureOxygen hoods/helmets as compared to conventional high-flow oxygen delivery systems.

MAIN OUTCOME(S) AND MEASURE(S): 1) Pre and post change in oxygen saturation (SaO2). 2) In-hospital Mechanical Ventilation (MV). 3) In-hospital Mortality. 4) Length of hospitalization.

RESULTS: 136 patients including 58-intervention and 78-control patients were studied. Age, gender, and other demographics/prognostic indicators were comparable between cohorts. Oxygen hoods averted imminent or immediate intubation/MV in all 58 COVID-19 patients failing on conventional high-flow oxygen delivery systems with a mean improvement in SaO2 of 8.8%, p < 0.001. MV rates were observed to be higher in the control 37/78 (47.4%) as compared to the intervention cohort 23/58 (39.7%), a difference of 7.7%, a 27% risk reduction, not statistically significant, OR 95%CI 0.73 (0.37-1.5). Mortality rates were observed higher in the control 54/78 (69.2%) as compared to the intervention cohort 36/58 (62.1%), a difference of 7.1%, a 27% risk reduction, not statistically significant OR 95%CI 0.73 (0.36-1.5).

CONCLUSION: Oxygen hoods demonstrate improvement in SaO2 for patients failing on conventional high-flow oxygen-delivery systems and prevented imminent mechanical ventilation. In-hospital mechanical ventilation and mortality rates were reduced with the use of oxygen hoods but not found to be statistically significant. The oxygen hood is a safe, effective oxygen-delivery system which may reduce intubation/MV and mortality rates. Their use should be considered in treating hypoxic COVID-19 patients. Further research is warranted.

TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04407260.

PMID:33636568 | DOI:10.1016/j.rmed.2021.106312