Categories
Nevin Manimala Statistics

Ultrasonic surgical and electrosurgical system (USES) with conventional ultrasonic scalpel (CUS) in gastrectomy: a retrospective cohort study

Cost Eff Resour Alloc. 2022 May 7;20(1):21. doi: 10.1186/s12962-022-00344-5.

ABSTRACT

BACKGROUND: Harmonic ACE +7 Shears with Advanced Hemostasis is an upgraded ultrasonic device, an ultrasonic surgical and electrosurgical system (USES). The study aimed to evaluate the economic and clinical effectiveness of the USES compared with the conventional ultrasonic scalpel (CUS) in gastrectomy.

METHODS: We conducted a single-center, retrospective cohort study using the electronic medical records in China. We collected intraoperative and postoperative data from gastric cancer patients who underwent the endoscope-assisted distal gastrectomy from 2018 to June 30, 2019. Procedure-related costs were estimated. We used linear regression by controlling a set of covariates to assess the effect of USES on outcomes.

RESULT: Out of 87 eligible patients, the USES group (40 patients) and CUS group (47 patients) were comparable in terms of age, medical history and stages of cancer. Compared with the CUS, the USES saved 4.27 hemoclips per person (95% CI 0.57-7.97, p < 0.05) and 34.18 ml intraoperative blood per person (95% CI 8.74-59.62 ml, p < 0.05), respectively. Postoperative length of stay (LOS) was shorter in the USES group (7.90 ± 1.95 vs. 9.26 ± 2.81 days) but the difference was not statistically significant (p = 0.05).

CONCLUSIONS: The USES group was associated with fewer hemoclips use and intraoperative blood loss in patients undergoing laparoscopic gastrectomy at comparable costs.

PMID:35525958 | DOI:10.1186/s12962-022-00344-5

By Nevin Manimala

Portfolio Website for Nevin Manimala