J Contemp Dent Pract. 2022 May 1;23(5):492-496.

ABSTRACT

AIM: The aim of the study was to compare the bond strength of three cantilever resin-bonded bridge (RBB) designs cemented with resin cements.

MATERIALS AND METHODS: Twenty-four extracted human mandibular canines with eight teeth per group were used in this study to evaluate the bond strength of cantilever resin-retained bridge designs of the mesh, perforated, and combination of mesh and perforated luted to the prepared lingual surface of canine teeth using resin cement. Debonding was done using Instron universal testing machine by applying load on the mid-buccal region of the pontic and the obtained values were evaluated. The data was analyzed statistically.

RESULTS: The mean shear bond strengths of mesh, perforated, and combination of mesh and perforated are 0.88 ± 0.31 MPa, 0.81 ± 0.31 MPa, and 0.93 ± 0.32 MPa. However, there is no significant differences in the statistical analysis that were performed using a one-factor analysis of variant (ANOVA) test (p = 0.744).

CONCLUSION: Within the limitation of this study for cantilever resin-retained bridge designs, the combination of mesh and perforated design showed greater mean shear bond values when compared with the mesh design and perforated designs. This shows equal in vitro performance to the gold standard designs (group A is mesh design and group B is perforated design).

CLINICAL SIGNIFICANCE: The new design which is the combination of mesh and perforated shows equal in vitro performance to the gold standard designs. Thus, their use in clinical situation can bring better result in concern to cantilever resin-retained prosthesis.

PMID:35986455