Am J Dent. 2022 Aug;35(2):200-204.

ABSTRACT

PURPOSE: To evaluate the effects of ultrasonic scaling (US) and air polishing (AP) on four polyetheretherketone (PEEK) composites.

METHODS: One hundred-twenty 15 × 3 mm discs of PEEK specimens were divided into four groups (n=30): Unfilled PEEK(U-PEEK), carbon fiber-reinforced PEEK(CFR-PEEK), glass fiber-reinforced PEEK(GFR-PEEK), and ceramic-filled PEEK(CF-PEEK). Each group was further divided into three subgroups (n = 10): control, US, and AP. Profilometry and scanning electron microscopy were used to analyze and evaluate surface roughness (SR). Statistical analyses of the data obtained were conducted using Shapiro-Wilk, Welch, and Games-Howell tests.

RESULTS: When the SR values of the specimens with US cleaning were evaluated, a statistically significant difference was found between the groups (P< 0.05). When the SR values of the specimens with AP cleaning were analyzed, there was a statistically significant difference in the CF-PEEK group (P< 0.05), whereas the other groups were not significantly different (P> 0.05). More studies are needed on CFR-PEEK and GFR-PEEK materials offered as alternatives to CF-PEEK in dentistry.

CLINICAL SIGNIFICANCE: Dental instruments affect the different PEEK materials, as well as causing surface roughness in many restorative materials used in dentistry. Surface roughness that occurs in dental restorations can cause bacterial adhesion. It is clinically important to choose the dental instrument according to the type of PEEK used for dental implant or prosthetic restoration in the clinic.

PMID:35986936

By Nevin Manimala

Portfolio Website for Nevin Manimala