Value of low-keV virtual monoenergetic plus dual-energy computed tomographic imaging for detection of acute pulmonary embolism

PLoS One. 2022 Nov 11;17(11):e0277060. doi: 10.1371/journal.pone.0277060. eCollection 2022.

ABSTRACT

OBJECTIVE: To compare diagnostic values between the 40 keV virtual monoenergetic plus (40 keV VMI+) dual source dual energy computed tomography (DSDECT) pulmonary angiography images and the standard mixed (90 and 150 kV) images for the detection of acute pulmonary embolism (PE).

METHODS: Chest DSDECTs of 64 patients who were suspected of having acute PE were retrospectively reviewed by two independent reviewers. The assessments of acute PE of all patients on a per-location basis were compared between the 40 keV VMI+ and the standard mixed datasets (reference standard) with a two-week interval.

RESULTS: This study consisted of 64 patients (33 women and 31 men; mean age, 60.2 years; range 18-90 years), with a total of 512 locations. The interobserver agreement (Kappa) for detection of acute PE using the 40 keV VMI+ images and the standard mixed CT images were 0.7478 and 0.8750 respectively. The area under receiver operating characteristics (AuROC) for diagnosis of acute PE using the 40 keV VMI+ was 0.882. Four locations (0.78%) revealed a false negative result. Hypodense filling defects were identified in twelve locations (1.95%) in the 40 keV VMI+ images but had been interpreted as a negative study in the standard mixed CT images. The repeated reviews revealed that each location contained a hypodense filling defect but was overlooked on the standard mixed CT images.

CONCLUSIONS: Low-energy VMI + DSDECT images have beneficial in improving the diagnostic value of acute PE in doubtful or disregarded standard mixed images.

PMID:36367855 | DOI:10.1371/journal.pone.0277060