Categories
Nevin Manimala Statistics

Selecting the lowest instrumented vertebra in a multilevel posterior cervical fusion across the cervicothoracic junction: a biomechanical investigation

J Neurosurg Spine. 2022 Dec 16:1-7. doi: 10.3171/2022.10.SPINE22381. Online ahead of print.

ABSTRACT

OBJECTIVE: Posterior cervical fusion is a common surgical treatment for patients with myeloradiculopathy or regional deformity. Several studies have found increased stresses at the cervicothoracic junction (CTJ) and significantly higher revision surgery rates in multilevel cervical constructs that terminate at C7. The purpose of this study was to investigate the biomechanical effects of selecting C7 versus T1 versus T2 as the lowest instrumented vertebra (LIV) in multisegmental posterior cervicothoracic fusion procedures.

METHODS: Seven fresh-frozen cadaveric cervicothoracic spines (C2-L1) with ribs intact were tested. After analysis of the intact specimens, posterior rods and lateral mass screws were sequentially added to create the following constructs: C3-7 fixation, C3-T1 fixation, and C3-T2 fixation. In vitro flexibility tests were performed to determine the range of motion (ROM) of each group in flexion-extension (FE), lateral bending (LB), and axial rotation (AR), and to measure intradiscal pressure of the distal adjacent level (DAL).

RESULTS: In FE, selecting C7 as the LIV instead of crossing the CTJ resulted in the greatest increase in ROM (2.54°) and pressure (29.57 pound-force per square inch [psi]) at the DAL in the construct relative to the intact specimen. In LB, selecting T1 as the LIV resulted in the greatest increase in motion (0.78°) and the lowest increase in pressure (3.51 psi) at the DAL relative to intact spines. In AR, selecting T2 as the LIV resulted in the greatest increase in motion (0.20°) at the DAL, while selecting T1 as the LIV resulted in the greatest increase in pressure (8.28 psi) in constructs relative to intact specimens. Although these trends did not reach statistical significance, the observed differences were most apparent in FE, where crossing the CTJ resulted in less motion and lower intradiscal pressures at the DAL.

CONCLUSIONS: The present biomechanical cadaveric study demonstrated that a cervical posterior fixation construct with its LIV crossing the CTJ produces less stress in its distal adjacent discs compared with constructs with C7 as the LIV. Future clinical testing is necessary to determine the impact of this finding on patient outcomes.

PMID:36681959 | DOI:10.3171/2022.10.SPINE22381

By Nevin Manimala

Portfolio Website for Nevin Manimala