Am J Sports Med. 2023 Mar 14:3635465231159069. doi: 10.1177/03635465231159069. Online ahead of print.

ABSTRACT

BACKGROUND: Persistent instability of the knee is reported in up to 30% of patients after anterior cruciate ligament (ACL) reconstruction. Based on anatomic findings showing that ACL is a flat ribbon-like structure that twists during knee flexion, a new surgical ACL reconstruction technique using a ribbon-like graft has been developed. However the effect of this surgical technique on knee kinematics has not yet been evaluated.

PURPOSE: To compare the anteroposterior and rotational stability of the knee after ACL reconstruction using single-bundle (SB) round and ribbon-like grafts in anterolateral-intact/deficient knees.

STUDY DESIGN: Controlled laboratory study.

METHODS: Twelve human fresh-frozen cadaveric knees were tested with a 6 degrees of freedom robotic system. Internal rotation and anterior translation of the knee were recorded from 0° to 90° of flexion. A full kinematic assessment was performed in each of the following conditions: (1) intact knee, (2) after sectioning of the ACL, (3) after ACL reconstruction using a SB hamstring tendon graft in a round configuration and a ribbon-like configuration, and (4) after sectioning of the anterolateral structures. One-way analysis of variance and post hoc Tukey tests were used for statistical analyses.

RESULTS: When compared with the intact knee, the ACL-deficient knee demonstrated a mean ± SD increase in anterior translation and internal rotation of 6.3 ± 2.5 mm (P < .01) and 5.8°± 2.3° (P < .01), respectively. After ACL reconstruction using a SB ribbon-like graft, the mean difference in anterior translation and internal rotation as compared with the intact knee was -0.1 ± 1.5 mm (P = .842) and 0.0°± 1.1° (P = .999). These differences from the intact knee were also not significant after ACL reconstruction using a round graft (-0.1 ± 1.3 mm, P = .999; -0.5°± 1.5°, P = .401). In the ACL-reconstructed knee using either a ribbon-like or round graft, sectioning of the anterolateral structures did not induce a significant increase of anterior translation and internal rotation of the knee.

CONCLUSION: ACL reconstruction using a SB ribbon-like or round graft restored the kinematics of the intact knee at time zero. Secondary sectioning of the anterolateral structures in the ACL-reconstructed knee using both types of graft did not significantly affect the anterior translation and internal rotation of the knee.

CLINICAL RELEVANCE: This is the first biomechanical study on the new ACL reconstruction technique using a ribbon-like graft.

PMID:36917792 | DOI:10.1177/03635465231159069