Categories
Nevin Manimala Statistics

Early outcomes of umbilical hernia repair with mesh suture

Hernia. 2026 Jul 29;30(1):304. doi: 10.1007/s10029-026-03798-1.

ABSTRACT

PURPOSE: Mesh suture is a suture device designed to distribute pressure at the suture-tissue interface to decrease suture pull-through. The primary aim of this study was to evaluate the feasibility and short-term clinical outcomes in isolated umbilical hernia repairs.

METHODS: A retrospective cohort of patients undergoing umbilical hernia repair using mesh suture was analyzed between January 2023-2025. Patients were identified through institutional implant logs. Outcomes evaluated included surgical site infection (SSI), surgical site events (SSE), hernia recurrence, readmissions, and reoperations.

RESULTS: Fifty-eight isolated umbilical hernia repairs with mesh suture were performed by twenty-four surgeons. The mean hernia width was 1.7 cm (± 0.7). The 90-day SSI rate was 5.2% (n = 3), consisting of two superficial infections and one organ space infection. The 90-day SSE rate was 5.2% (n = 1 fascial dehiscence, n = 2 hematomas). There were seven readmissions (12.1%) within 90 days, of which only one was related to the abdominal wall closure. There were three reoperations within 90 days (5.2%): two hematoma washouts and one fascial dehiscence repair. The mean length of follow up was 594 days (± 284). There were no cases of hernia recurrence.

CONCLUSIONS: Mesh suture provides the simplicity of suture repair with increased force distribution properties of mesh. In this initial multicenter experience, mesh suture demonstrated feasibility and acceptable short-term clinical outcomes for isolated umbilical hernia repair. Future randomized controlled trials comparing mesh suture versus planar mesh and standard suture are needed to compare techniques most effectively.

PMID:42525301 | DOI:10.1007/s10029-026-03798-1