Categories
Nevin Manimala Statistics

Evaluation of direct restorations using the revised FDI criteria: results from a reliability study

Clin Oral Investig. 2022 Nov 18. doi: 10.1007/s00784-022-04771-9. Online ahead of print.

ABSTRACT

OBJECTIVES: The purpose of this in vitro reliability study was to determine the intra- and inter-examiner agreement of the revised FDI criteria including the categories “fracture of material and retention” (F1) and “caries at restoration margin” (B1).

MATERIALS AND METHODS: Forty-nine photographs of direct tooth-coloured posterior (n = 25) and anterior (n = 24) restorations with common deficiencies were included. Ten dental experts repeated the assessment in three blinded rounds. Later, the experts re-evaluated together all photographs and agreed on a reference standard. Statistical analysis included the calculation of Cohen’s (Cκ), Fleiss’ (Fκ), and weighted Kappa (wκ), the development of a logistic regression with a backward elimination model and Bland/Altman plots.

RESULTS: Intra- and inter-examiner reliability exhibited mostly moderate to substantial Cκ, Fκ, and wκ values for posterior restorations (e.g. Intra: F1 Cκ = 0.57, wκ = 0.74; B1 Cκ = 0.57, wκ = 0.73/Inter F1 Fκ = 0.32, wκ = 0.53; B1 Fκ = 0.41, wκ = 0.64) and anterior restorations (e.g. Intra F1 Cκ = 0.63, wκ = 0.76; B1 Cκ = 0.48, wκ = 0.68/Inter F1 Fκ = 0.42, wκ = 0.57; B1 Fκ = 0.40, wκ = 0.51). Logistic regression analyses revealed significant differences between the evaluation rounds, examiners, categories, and tooth type. Both the intra- and inter-examiner reliability increased along with the evaluation rounds. The overall agreement was higher for anterior restorations compared to posterior restorations.

CONCLUSIONS: The overall reliability of the revised FDI criteria set was found to be moderate to substantial.

CLINICAL RELEVANCE: If properly trained, the revised FDI criteria set are a valid tool to evaluate direct and indirect restorations in a standardized way. However, training and calibration are needed to ensure reliable application.

PMID:36399211 | DOI:10.1007/s00784-022-04771-9

By Nevin Manimala

Portfolio Website for Nevin Manimala