Categories
Nevin Manimala Statistics

Short-term curative effect and safety on female abdominal obesity and defecation function treated with acupoint embedding therapy at different layers under B ultrasound

Zhen Ci Yan Jiu. 2022 Jan 25;47(1):53-8. doi: 10.13702/j.1000-0607.201042.

ABSTRACT

OBJECTIVE: To investigate the short-term effect and safety on female abdominal obesity and defecation function in treatment with acupoint embedding therapy at different abdominal layers under B ultrasound.

METHODS: A total of 102 female patients with abdominal obesity were randomly divided into 3 groups, i.e. a deep embedding group (34 cases, 1 case dropped out), a shallow embedding group (34 cases, 3 cases dropped out) and a sham-embedding group (34 cases, 6 cases dropped out). Finally, 92 cases were included in the three groups. Under B ultrasound, in the deep embedding group, the absor-bable surgical suture were embedded in subcutaneous fat layer and muscle layer. In the shallow embedding group, the absorbable surgical suture was embedded in the fat layer and in the sham-embedding group, no suture was embedded. The acupoints for embedding therapy included Zhongwan (CV12), Guanyuan (CV4), bilateral Guanmen (ST22), bilateral Tianshu (ST25), bilateral Daimai (GB26) and bilateral Shuidao (ST28). The acupoint embedding therapy was exerted once every two weeks, for 4 times totally. Before and after treatment, the changes in abdominal obesity indicators (waist circumference [WC], body fat rate [BFR], body mass index [BMI], abdominal subcutaneous fat thickness [ASFT]) and defecation function indicators (spontaneous bowel movement times [SBMs] and Bristol stool scale [BSS]) were observed and the safety indicators were assessed.

RESULTS: After treatment, WC, BFR, BMI and ASFT were lower than those before treatment in both the deep embedding group and the shallow embedding group (P<0.05), those values in the deep embedding group were reduced more obviously as compared with the shallow embedding group (P<0.05). SBMs and BSS after treatment were increased as compared with those before treatment in both the deep embedding group and the shallow embedding group (P<0.05) and the increase in the deep embedding group was more obvious than in the shallow embedding group (P<0.05). The abdominal obesity indicators and defecation function indicators after treatment were not different statistically as compared with those before treatment in the sham-embedding group (P>0.05). The pain score of acupuncture in either the deep embedding group or the shallow embedding group was higher than in the sham-embedding group (P<0.05). The acceptance was more than 2 points in all of the three groups and there was no statistical significance among groups (P>0.05).

CONCLUSION: Acupoint embedding therapy in both the deep and the shallow subcutaneous layers under B ultrasound may regulate the indicators of female abdominal obesity safely. The acupoint embedding therapy in the deep layer is more effective on abdominal obesity and defecation improvement as compared with that exerted in the shallow layer.

PMID:35128871 | DOI:10.13702/j.1000-0607.201042

Categories
Nevin Manimala Statistics

Effect of transcutaneous auricular vagus nerve stimulation on the expressions of GFAP and MAP2 in ischemic penumbra of rats with middle cerebral artery ischemia

Zhen Ci Yan Jiu. 2022 Jan 25;47(1):33-8. doi: 10.13702/j.1000-0607.20210059.

ABSTRACT

OBJECTIVE: To observe the effects of transcutaneous auricular vagus nerve stimulation (taVNS) on the motor function and the expression of glial fibrillary acidic protein (GFAP) and microtubule associated protein 2 (MAP2) in cerebral ischemic penumbra of rats with middle cerebral artery occlusion (MCAO) and explore the mechanism of taVNS in the improvement of motor function in MCAO rats.

METHODS: A total of 48 male SD rats were randomized into a sham-operation group, a model group, a transcutaneous auricular non-vagus nerve stimulation (tnVNS) group and a taVNS group, with 12 rats in each group. The suture-occluded method was adopted to prepare MCAO rat model. The auricular rim was stimulated in the tnVNS group and the concha stimulated in the taVNS group, 2 mA in intensity, 10 Hz in frequency, 30 min each time, once a day, for 14 days consecutively. The nerve functional assessment was recorded in each group. The expressions of nicotinic acetylcholine receptor (α7nAchR) in the cerebral ischemic penumbra and the spleen were detected by using Western blot. With the immunofluorescence, the expressions of GFAP and MAP2 were detected.

RESULTS: After modeling, compared with the sham-operation group, the nerve functional score was increased in the model group, the tnVNS group and the taVNS group (P<0.01), suggesting the success of modeling. After treatment, the score was increased in the model group (P<0.01) as compared with the sham-operation group. Compared with the model group, the neurological deficit score was reduced in the taVNS group (P<0.01). Compared with the sham-operation group, GFAP expression was increased and MAP2 expression was reduced remarkably in the cerebral ischemic penumbra in the model group (P<0.05). In comparison with the model group, GFAP expression was reduced, while MAP2 expression was increased remarkably in the cerebral ischemic penumbra in the taVNS group (P<0.05). There were no significant differences in the abovementioned indexes between the model group and tnVNS group (P>0.05). The differences in the expression of α7nAchR in the cerebral ischemic penumbra and the spleen had no statistical significance among groups (P>0.05).

CONCLUSION: TaVNS is effective on neuroprotection in MCAO rats, which may be related to its function of inhibition of GFAP expression and promotion of MAP2 expression in the ischemic penumbra.

PMID:35128868 | DOI:10.13702/j.1000-0607.20210059

Categories
Nevin Manimala Statistics

Electroacupuncture ameliorates ischemic injury in cerebral ischemia-reperfusion rats by regulating endogenous melatonin and inhibiting the activation of astrocytes

Zhen Ci Yan Jiu. 2022 Jan 25;47(1):39-45. doi: 10.13702/j.1000-0607.20210738.

ABSTRACT

OBJECTIVE: To observe the effect of electroacupuncture(EA)at “Baihui”(GV20) and “Shenting” (GV24) on the expression of melatonin synthesis rate-limiting enzyme-arylalkylamine N-acetyltransferase(AANAT)in pineal gland of rats with focal cerebral ischemia-reperfusion injury, so as to explore the mechanism of EA underlying improving ischemia-reperfusion injury.

METHODS: Forty-eight SD rats were randomly divided into sham operation, model, EA and non-acupoint groups, with 12 rats in each group. The focal cerebral ischemia-reperfusion injury rat model was established by occlusion of the middle cerebral artery. Rats of the EA group received EA at GV20 and GV24, while those in the non-acupoint group received EA at non-acupoints below the costal margins on both sides for 20 min, once daily for 7 days. The neurological deficit score (0 to 4 points) was given after successful modeling according to Longa’s method. Morris water maze test was used to assess the cognitive function of rat. ELISA was used to detect the plasma melatonin content, and PCR and Western blot were used to detect the mRNA and protein expressions of AANAT in the pineal gland, separately. Immunofluorescence staining was used to detect the activation of astrocytes and neuronal injury in the hippocampus.

RESULTS: After focal cerebral ischemia-reperfusion injury and compared with the sham operation group, the neurological deficit score, the escape latency, and the expression of GFAP were significantly increased (P<0.01),while the times of platform quadrant crossing, the secretion of melatonin at 24:00,AANAT mRNA and protein expression levels and NeuN protein expression were significantly down-regulated (P<0.01). After EA at GV20 and GV24, the above-mentioned indexes all reversed in the EA group relative to the model group, and there were significant differences between the two groups(P<0.01). Compared with the model group, the changes of the abovementioned indexes in the non-acupoint group were not statistically significant (P>0.05).

CONCLUSION: EA at GV20 and GV24 can alleviate neurological deficit and improve cognitive function in cerebral ischemia-reperfusion rats,which may be related to its effects in up-regulating endogenous melatonin levels, inhibiting the activation of astrocytes and protecting damaged neurons in the hippocampus.

PMID:35128869 | DOI:10.13702/j.1000-0607.20210738

Categories
Nevin Manimala Statistics

Clinicopathologic and protein markers distinguishing the “polymerase epsilon exonuclease” from the “copy number low” subtype of endometrial cancer

J Gynecol Oncol. 2022 Jan 17. doi: 10.3802/jgo.2022.33.e27. Online ahead of print.

ABSTRACT

OBJECTIVE: The need to perform genetic sequencing to diagnose the polymerase epsilon exonuclease (POLE) subtype of endometrial cancer (EC) hinders the adoption of molecular classification. We investigated clinicopathologic and protein markers that distinguish the POLE from the copy number (CN)-low subtype in EC.

METHODS: Ninety-one samples (15 POLE, 76 CN-low) were selected from The Cancer Genome Atlas EC dataset. Clinicopathologic and normalized reverse phase protein array expression data were analyzed for associations with the subtypes. A logistic model including selected markers was constructed by stepwise selection using area under the curve (AUC) from 5-fold cross-validation (CV). The selected markers were validated using immunohistochemistry (IHC) in a separate cohort.

RESULTS: Body mass index (BMI) and tumor grade were significantly associated with the POLE subtype. With BMI and tumor grade as covariates, 5 proteins were associated with the EC subtypes. The stepwise selection method identified BMI, cyclin B1, caspase 8, and X-box binding protein 1 (XBP1) as markers distinguishing the POLE from the CN-low subtype. The mean of CV AUC, sensitivity, specificity, and balanced accuracy of the selected model were 0.97, 0.91, 0.87, and 0.89, respectively. IHC validation showed that cyclin B1 expression was significantly higher in the POLE than in the CN-low subtype and receiver operating characteristic curve of cyclin B1 expression in IHC revealed AUC of 0.683.

CONCLUSION: BMI and expression of cyclin B1, caspase 8, and XBP1 are candidate markers distinguishing the POLE from the CN-low subtype. Cyclin B1 IHC may replace POLE sequencing in molecular classification of EC.

PMID:35128857 | DOI:10.3802/jgo.2022.33.e27

Categories
Nevin Manimala Statistics

Estimands in observational studies: Some considerations beyond ICH E9 (R1)

Pharm Stat. 2022 Feb 6. doi: 10.1002/pst.2196. Online ahead of print.

ABSTRACT

The document ICH E9 (R1) has brought much attention to the concept of estimand in the clinical trials community. ICH stands for International Conference for Harmonization. In this article, we draw attention to one facet of estimand that is not discussed in that document but is crucial in the context of observational studies, namely weighting for covariate balance. How weighting schemes are connected to estimand, or more specifically to one of its five attributes identified in ICH E9 (R1), the attribute of population, is illustrated using the Rubin Causal Model. Three estimands are examined from both theoretical and practical perspectives. Factors that may be considered in choosing among these estimands are discussed.

PMID:35128808 | DOI:10.1002/pst.2196

Categories
Nevin Manimala Statistics

A prospective comparison of the diagnostic accuracies of ultrasound and magnetic resonance imaging in preoperative staging of endometrial cancer

J Gynecol Oncol. 2022 Jan 17. doi: 10.3802/jgo.2022.33.e22. Online ahead of print.

ABSTRACT

OBJECTIVE: To compare the diagnostic accuracies of ultrasound and magnetic resonance imaging (MRI) for deep (≥50%) myometrial invasion (DMI) and cervical stromal invasion (CSI) in women with endometrial cancer.

METHODS: This was a prospective study at a gynecology clinic for women with postmenopausal bleeding. Between October 2015-October 2018, consecutive women with suspected endometrial cancer based on ultrasound subjective pattern recognition were simultaneously assessed for DMI and CSI on ultrasound. Subsequently, they also underwent preoperative MRI. We compared the diagnostic accuracies of ultrasound and MRI in predicting DMI and CSI with the final histology as the gold standard.

RESULTS: We included 51 women. The prevalence of DMI and CSI were 22/51 (43%) and 7/51 (14%), respectively. The majority of malignancies were of endometrioid histological subtype (38/51, 75%) and FIGO stage 1 or 2 (40/51, 78%). Ultrasound diagnosed more cases of DMI compared to MRI (19/22 vs. 17/22), however, the difference was not statistically significant. The sensitivities and specificities of ultrasound and MRI for DMI were 86% vs. 77% and 66% vs. 76%, respectively. For CSI, ultrasound and MRI correctly diagnosed the same number of cases (5/7, 71%); their respective false-positive rates were low, 0/44 (0%) and 1/44 (2%). Ultrasound and MRI had a moderate agreement for DMI (ƙ=0.49; 95% confidence interval [CI]=0.26-0.73), whereas the agreement for CSI was substantial (ƙ=0.69; 95% CI=0.36-1.00).

CONCLUSION: Endometrial cancer can be simultaneously diagnosed and staged at women’s initial ultrasound assessment. The accuracies of ultrasound for DMI and CSI are comparable to MRI.

TRIAL REGISTRATION: ISRCTN Identifier: ISRCTN24363390.

PMID:35128854 | DOI:10.3802/jgo.2022.33.e22

Categories
Nevin Manimala Statistics

Comparison of visual shade matching and photographic shade analysis

J Esthet Restor Dent. 2022 Feb 6. doi: 10.1111/jerd.12883. Online ahead of print.

ABSTRACT

OBJECTIVE: To compare the performance of a standardized photographic shade analysis (PSA) and visual shade matching (VSM) using two color difference formulas.

MATERIALS AND METHODS: Fifty observers (35 undergraduate and 15 graduate students) evaluated the color of two upper left central incisors (LT-light tooth, and DT-dark tooth). VSM was performed using the VITA 3D Master (3D) shade guide in a controlled clinical environment. For PSA, a cross-polarized filter and a gray card (Whibal) were used to standardize the photographs taken (target teeth and shade tabs from 3D). From the pictures obtained, the CIELAB coordinates, and color differences ( ΔEab* and ΔE00 ) were obtained. The shade tabs selected by two experienced researchers were conducted as part of the pilot study, and finally used as a standard for the analysis. Data were analyzed using descriptive statistics and the chi-square test (p ≤ 0.05).

RESULTS: Shade tabs selections of VSM and PSA agreed only for LT. The best “Match” selected by the researchers agreed with data from PSA using ΔE00 . PSA using ΔE00 showed higher total percentages of “Match” and higher percentage of agreement among observers. A relationship was found for LT performing the PSA (p < 0.05).

CONCLUSIONS: The performance of the PSA was better than the VSM, but only when the CIEDE2000 color difference formula was used. Therefore, the color difference formulas influenced on the performance of PSA. Finally, the PSA improved the precision of the VSM.

CLINICAL SIGNIFICANCE: To use a standardized PSA to improve the VSM and shade communication in clinical esthetic dentistry.

PMID:35128799 | DOI:10.1111/jerd.12883

Categories
Nevin Manimala Statistics

Incorporating historical controls in clinical trials with longitudinal outcomes using the modified power prior

Pharm Stat. 2022 Feb 6. doi: 10.1002/pst.2195. Online ahead of print.

ABSTRACT

Several dynamic borrowing methods, such as the modified power prior (MPP), the commensurate prior, have been proposed to increase statistical power and reduce the required sample size in clinical trials where comparable historical controls are available. Most methods have focused on cross-sectional endpoints, and appropriate methodology for longitudinal outcomes is lacking. In this study, we extend the MPP to the linear mixed model (LMM). An important question is whether the MPP should use the conditional version of the LMM (given the random effects) or the marginal version (averaged over the distribution of the random effects), which we refer to as the conditional MPP and the marginal MPP, respectively. We evaluated the MPP for one historical control arm via a simulation study and an analysis of the data of Alzheimer’s Disease Cooperative Study (ADCS) with the commensurate prior as the comparator. The conditional MPP led to inflated type I error rate when there existed moderate or high between-study heterogeneity. The marginal MPP and the commensurate prior yielded a power gain (3.6%-10.4% vs. 0.6%-4.6%) with the type I error rates close to 5% (5.2%-6.2% vs. 3.8%-6.2%) when the between-study heterogeneity is not excessively high. For the ADCS data, all the borrowing methods improved the precision of estimates and provided the same clinical conclusions. The marginal MPP and the commensurate prior are useful for borrowing historical controls in longitudinal data analysis, while the conditional MPP is not recommended due to inflated type I error rates.

PMID:35128780 | DOI:10.1002/pst.2195

Categories
Nevin Manimala Statistics

Feasibility of using ring-mounted Halcyon Linac for single-isocenter/two-lesion lung stereotactic body radiation therapy

J Appl Clin Med Phys. 2022 Feb 7:e13555. doi: 10.1002/acm2.13555. Online ahead of print.

ABSTRACT

PURPOSE: To demonstrate the plan quality and delivery efficiency of volumetric-modulated arc therapy (VMAT) with the Halcyon Linac ring delivery system (RDS) in the treatment of single-isocenter/two-lesion lung stereotactic body radiation therapy (SBRT).

MATERIALS/METHODS: Sixteen previously treated non-coplanar VMAT single-isocenter/two-lesion lung SBRT plans delivered with SBRT-dedicated C-arm TrueBeam Linac were selected. Prescribed dose was 50 Gy to each lesion over five fractions with treatment delivery every other day and AcurosXB algorithm as the final dose calculation algorithm. TrueBeam single-isocenter plans were reoptimized for Halcyon Linac with coplanar geometry. Both TrueBeam and Halcyon plans were normalized for identical combined target coverage and evaluated. Conformity indices (CIs), heterogeneity index (HI), gradient index (GI), gradient distance (GD), and D2cm were compared. The normal lung V5Gy, V10Gy, V20Gy, mean lung dose (MLD), and dose to organs at risk (OAR) were evaluated. Treatment delivery parameters, including beam-on time, were recorded.

RESULTS: Halcyon plans were statistically similar to clinically delivered TrueBeam plans. No statistical differences in target conformity, dose heterogeneity, or intermediate-dose spillage were observed (all, p > 0.05). Halcyon plans, on average, demonstrated statistically insignificant reduced maximum dose to most adjacent OAR and normal lung. However, Halcyon yielded statistically significant lower maximal dose to the ribs (p = 0.041) and heart (p = 0.026), dose to 1 cc of ribs (p = 0.035) and dose to 5 cc of esophagus (p = 0.043). Plan complexity slightly increased as seen in the average increase of total monitor units, modulation factor, and beam-on time by 480, 0.48, and 2.78 min, respectively. However, the estimated overall treatment time was reduced by 2.22 min, on average. Mean dose delivery accuracy of clinical TrueBeam plans and the corresponding Halcyon plans was 98.9 ± 0.85% (range: 98.1%-100%) and 98.45 ± 0.99% (range: 97.9%-100%), respectively, demonstrating similar treatment delivery accuracy.

CONCLUSION: SBRT treatment of synchronous lung lesions via single-isocenter VMAT on Halcyon RDS is feasible and dosimetrically equivalent to clinically delivered TrueBeam plans. Halcyon provides excellent plan quality and shorter overall treatment time that may improve patient compliance, reduce intrafraction movement, improve clinic efficiency, and potentially offering lung SBRT treatments for underserved patients on a Halcyon only clinic.

PMID:35128795 | DOI:10.1002/acm2.13555

Categories
Nevin Manimala Statistics

The subjectively perceived injectability as an early indicator for adverse events?

J Cosmet Dermatol. 2022 Feb 6. doi: 10.1111/jocd.14697. Online ahead of print.

ABSTRACT

BACKGROUND: With an increasing demand of aesthetic soft-tissue filler treatments, the occurrence of adverse events rises likewise. An optimized injection algorithm adapted to product characteristics (eg, rheology) of the soft-tissue filler is crucial in order to ensure satisfying clinical outcomes and high patient safety.

OBJECTIVE: To identify a subjective feedback mechanism for the avoidance of adverse events after soft-tissue filler injection procedures.

METHODS: A retrospective data analysis of n = 387 aesthetic treatments performed on n = 291 patients (4 males, 287 females) with different soft-tissue fillers with regard to loss of volume (filling effect), injected layer, injectability (“ease of injection”), injected volume, and injection technique was conducted.

RESULTS: The subjectively perceived injectability during the injection process was statistically significantly related to G-Prime value with rs = 0.101 with p = 0.048, indicating an increased difficulty while injecting products with higher G-Prime. The occurrence of adverse events was also statistically significantly related to the injectability: injections with increased subjectively perceived difficulty showed increasing odds of developing adverse events by OR 0.157 with p = 0.002.

CONCLUSION: Injections that were subjectively more difficult to perform are more likely to develop adverse events. Respecting the layered arrangement of the face, the recommended and approved depth and facial region for each specific treatment enable practitioners to achieve satisfying outcomes while keeping the rate of adverse events low.

PMID:35128773 | DOI:10.1111/jocd.14697